EasyManua.ls Logo

Panasonic CS-G123KE - Page 28

Panasonic CS-G123KE
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 31 –
MAC9509078C2
CS-G93KE
Operation Details
When the operation mode is changed over, the value for t1, t2 and t3 are shifted as follows:
Cooling/Soft dry Heating: –2°C
Heating Cooling/Soft dry: +2°C
When the indoor intake air temperature is lower than 16°C, heating operation is immediately started.
When the outdoor air temperature is more than 25°C, and the intake air temperature is over 16°C, cooling
operation is immediately started.
The operation mode is judged every 30 minutes.
When the operation mode (Heating, Cooling or Soft Dry) is decided, the internal setting temperature will shift
as shown below:
Remote Control Setting temperature
+
Outdoor temperature shift
+
Fan speed shift
+
Automatic mode shift
+
INTERNAL SETTING TEMPERATURE
Cooling
Soft Dry
Heating
+0.75°C
0°C
–0.75°C
Untitled-3 6/20/00, 5:03 PM31