– 31 –
MAC9509078C2
CS-G93KE
Operation Details
• When the operation mode is changed over, the value for t1, t2 and t3 are shifted as follows:
Cooling/Soft dry → Heating: –2°C
Heating → Cooling/Soft dry: +2°C
• When the indoor intake air temperature is lower than 16°C, heating operation is immediately started.
• When the outdoor air temperature is more than 25°C, and the intake air temperature is over 16°C, cooling
operation is immediately started.
• The operation mode is judged every 30 minutes.
• When the operation mode (Heating, Cooling or Soft Dry) is decided, the internal setting temperature will shift
as shown below:
Remote Control Setting temperature
+
Outdoor temperature shift
+
Fan speed shift
+
Automatic mode shift
+
↓
INTERNAL SETTING TEMPERATURE
Cooling
Soft Dry
Heating
+0.75°C
0°C
–0.75°C
Untitled-3 6/20/00, 5:03 PM31