– 41 –
MAC9509078C2
CS-G93KE
15. POWER MONITOR DISPLAY
Power Monitor LED lights on when the compressor is in operation. The number of the LED lights on is in accordance
to the compressor operating frequency.
Display
Cooling & Soft Dry
Indication Frequency
(Hz)
Heating Indication
Frequency (Hz)
Cooling & Soft Dry
Indication Frequency
(Hz)
Heating Indication
Frequency (Hz)
Operation Details
A, B, C, D
43 ~ 46
63 ~ 64
58 ~ 64
83 ~ 86
A, B, C
36 ~ 40
43 ~ 58
44 ~ 49
58 ~ 79
A, B
31 ~ 33
31 ~ 40
31 ~ 36
31 ~ 44
Model
CS-G93KE
CS-G123KE
A
15 ~ 26
15 ~ 26
15 ~ 27
15 ~ 27
A, B, C, D, E
51 ~ 64
71 ~ 99
71 ~ 92
91 ~ 115
Press the AUTO button for 10 seconds or longer to switch off the signal receiving sound.
Press the AUTO button for 10 seconds or longer again to switch on the signal receiving sound.
16. REMOTE CONTROL SIGNAL RECEIVING SOUND ON/OFF
The power relay turns on when one of the indoor LED lights on.
The power relay turns off when all of the indoor LEDs lights off.
When the air conditioner is stopped during operation, the power relay stays ON for 3 minutes.
The power relay will turn off if a sudden power failure occurs > 0.05 second. The power relay will turn on again
after 3 - 4 minutes (Refer AUTO RESTART CONTROL). It will start with the previous operation condition before
the power failure.
17. INDOOR POWER RELAY CONTROL
POWER SLEEP TIMER
POWER
MONITOR
POWERFUL
LOW
HIGH
A
C
DBE
Untitled-5 6/20/00, 5:11 PM41