– 3 –
CS-G93KE
Functions
Indoor Unit
Power Switch OFF / ON
LL
LL
L
Power Monitor Display
**
**
*
• Lights up during compressor operation.
Automatic Operation Switch
• Used when the remote control cannot be
used.
Remote Control Signal Receiving
Sound Control OFF/ON
**
**
*
• It can be controlled by pressing Automatic
Operation Switch for 10 seconds.
Test Run Operation
• Used when test running or servicing.
• Compressor operation: rated frequency
Cooling: 50Hz (CS-G93KE), 70Hz (CS-G123KE)
Heating: 71Hz (CS-G93KE), 90Hz (CS-G123KE)
Operation Mode
• Automatic, Heating, Cooling, Soft Dry and
Fan Operation.
Automatic Restart Control
**
**
*
• Operation is restarted after power failure at
previous setting mode.
POWER L
AUTO
OFF / ON
TEST RUN
OFF / ON
Operation Indication Lamps
• POWER (Red) – Lights up in opera-
tion,
blinks in Automatic
Operation judging
and Hot Start opera-
tion.
• TIMER (Orange) – Lights up in Timer
Setting.
Blinks in Self Diagno-
sis Control.
• SLEEP (Orange) – Lights up in Sleep
Mode Operation.
• POWERFUL (Orange) – Lights up when
Powerful mode is
selected
Sleep Operation Mode
**
**
*
Timer Operation
**
**
*
Powerful Mode
**
**
*
• For quick cooling or heating
Indoor Fan Speed Control
**
**
*
Airflow Direction Control
**
**
*
FOR ALL OPERATIONS
Untitled-1 6/20/00, 4:18 PM3