Before using the circuit diagram, read the following carefully.
* Voltage measurement
Voltage has been measured with a digital
tester at rated frequency.
Use them for servicing.
Voltage indication is in Red at cooling and all
operations.
Voltage indication is in (Red) at heating.
How to use electronic circuit diagram
* Indications for resistance
a. K .... kΩ M ... MΩ
W... watt Not indicated .... 1/4W
b. Type
Not indicated .......... carbon resister
Tolerance±5%
.......... metal oxide resister
Tolerance±1%
* Indications for capacitor
a. Unit µ ....µF P ....pF
b. Type Not indicated ...
ceramic capacitor
(S) ..........S series aluminium
electrolytic capacitor
(Z) .......... Z series aluminium
electrolytic capacitor
(SU) ....... SU series aluminium
electrolytic capacitor
(P) ..........
P series polyester system
(SXE) ..... SXE series aluminium
electrolytic capacitor
(SRA)...... SRA series aluminium
electrolytic capacitor
(KME)......KME series aluminium
electrolytic capacitor
* Diode without indication ..............MA165
* Circuit Diagram is subject to change without
notice for further development.
TIMER TABLE <INDOOR>
Name
4 way valve abnormality
Outdoor air temp. for Hz No. decision
Anti-dew formation control
Anti-freezing control
Thermo OFF delay
Low pressure control (gas leakage) compressor OFF time
Time delay safety control
Odour timer status shift time
Intake air temp. sampling time
Self diagnosis display time
Auto mode judgement sampling time
24 hours ON / OFF timer
Heating SSHi fan speed shift
Cooling SHi fan speed shift
Hot start forced completion
Anti-fog discharge control
Auto mode judgement interval
Sleep mode time shift
After Hot start / Deice
Time
4 min.
30 min.
20 min.
6 min.
3 min.
3 min.
2 min. 58 sec.
30 sec.
60 sec.
2 min.
10 sec.
20 sec.
120 min.
30 min.
4 min.
30 min.
90 min.
180 min.
420 min.
30 min.
2 min.
Test mode
When test point
short-circuited
2.4 sec.
0 sec.
0 sec.
0 sec.
0 sec.
0 sec.
0 sec.
0 sec.
0 sec.
0 sec.
0 sec.
1 hour → 1 min.
12 sec.
3 sec.
0 sec.
3 sec.
9 sec.
18 sec.
42 sec.
3 sec.
1 hour → 6 sec.
12 sec.
TIMER TABLE <OUTDOOR>
Name
DC PEAK
Deice detection
Deice forced completion
Hz lock time
Outdoor fan delay operation control
4 way valve delay operation control
Time
30 sec.
120 min.
80 min.
40 min.
40 min.
11 min.
30 sec.
30 sec.
3 min.
Test mode
When test point
short-circuited
3 sec.
24 sec.
16 sec.
8 sec.
8 sec.
66 sec.
0 sec.
3 sec.
18 sec.
ELECTRONIC CIRCUIT DIAGRAM
•