27
11.2. Indoor Unit
11.2.1. How To Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent
it from the vibration.
The centre of installation plate should be at more than 1 at
right and left of the wall.
The distance from installation plate edge to ceiling should more
than 2.
From installation plate left edge to unit's left side is 3.
From installation plate right edge to unit's right is 4.
B : For left side piping, piping connection for liquid should be
about 5 from this line.
: For left side piping, piping connection for gas should be
about 6 from this line.
1. Mount the installation plate on the wall with 5 screws or
more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using
anchor bolts.)
• Always mount the installation plate horizontally by
aligning the marking-off line with the thread and using a
level gauge.
2. Drill the piping plate hole with ø70 mm hole-core drill.
• Putting measuring tape at position as shown in the
diagram above.
The hole center is obtained by measuring the distance
namely 128 mm for left and right hole respectively.
Another method is intersection point of arrow mark
extension.
The meeting point of the extension arrow mark is the
hole center position.
• Drill the piping hole at either the right or the left and the
hole should be slightly slanting to the outdoor side. (refer
to step 3)
11.2.2. To Drill A Hole In The Wall And
Install A Sleeve Of Piping
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes about 15 mm from the
wall.
4. Finish by sealing the sleeve with putty or caulking
compound at the final stage.
11.2.3. Indoor Unit Installation
Model Dimension
C12***,
SC/PC12***
485 mm 82 mm 165 mm 158 mm 43 mm 95 mm
C18***,
SC/PC18***,
C24***,
SC/PC24***
585 mm 82 mm 165 mm 158 mm 109 mm 159 mm
Caution
When the wall is hollow, please be sure to use the sleeve for tube
assembly to prevent dangers caused by mice biting the connecting
cable.