39
Auto Fan Speed during Soft Dry operation:
1. Indoor fan will rotate alternately between off and Lo-.
2. At the beginning of each compressor start operation, indoor fan will increase fan speed gradually for deodorizing purpose.
3. When compressor at turn off condition for 6 minutes, indoor fan will start fan speed at Lo- to circulate the air in the room.
This is to obtain the actual reading of intake air temperature.
12.4.3. Manual Fan Speed Control
Manual fan speed adjustment can be carried out by using the Fan Speed selection button at the remote control.
There are 3 types of fan speed settings: Lo, Me, Hi.
12.4.4. Indoor Fan Motor RPM Abnormal Control
Immediate after the fan motor is started, rpm abnormal control is performed once every second.
During fan motor on, if fan motor feedback 2550 or <50 rpm continuously for 10 seconds, the fan motor error counter increased;
fan motor is then stopped and restarted. If the fan motor error counter increased to 7, the air conditioner will stop.
12.5. Outdoor Fan Speed Control
There is only one speed for outdoor fan motor.
When the air conditioner is turned on, the compressor and the outdoor fan will operate simultaneously.
Likewise, both compressor and outdoor fan will stop at the same time if the unit is turned off.