8
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2. Specification are subjected to change without prior notice for further improvement.
Dimension
Height (I/D / O/D) mm (inch) 290 (11-7/16) 540 (21-9/32) 290 (11-7/16) 750 (29-17/32)
Width (I/D / O/D) mm (inch) 1070 (42-5/32) 780 (30-23/32) 1070 (42-5/32) 875 (34-15/32)
Depth (I/D / O/D) mm (inch) 235 (9-9/32) 289 (11-13/32) 235 (9-9/32) 345 (13-19/32)
Weight Net (I/D / O/D) kg (lb) 12.0 (26) / 39.0 (86) 12.0 (26) / 56.0 (123)
Piping
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4”) / 12.70 (1/2”) 6.35 (1/4”) / 15.88 (5/8”)
Standard length m (ft) 5.0 (16.4) 5.0 (16.4)
Length range (min~max) m (ft) 3~25 (9.8~82.0) 3~25 (9.8~82.0)
I/D & O/D Height different m (ft) 20 (65.6) 20 (65.6)
Additional Gas Amount g/m (oz/ft) 20 (0.2) 30 (0.3)
Length for Additional Gas m (ft) 7.5 (24.6) 7.5 (24.6)
Drain Hose
Inner Diameter mm 14 14
Length mm 550 550
Indoor Heat Exchanger
Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat)
Fin Type Slit Fin Slit Fin
Row × Stage × FPI 2 × 15 × 21 2 × 15 × 21
Size (W × H × L) mm 810 × 315 × 25.4 810 × 315 × 25.4
Outdoor Heat Exchanger
Fin Material Aluminium (Blue Coat) Aluminium (Blue Coat)
Fin Type Slit Fin Slit Fin
Row × Stage × FPI 2 × 24 × 17 1 × 34 × 17
Size (W × H × L) mm 25.4 × 504 × 693.4: 713.4 25.4 × 714.0 × 826.2: 846.2
Air Filter
Material Polypropelene Polypropelene
Type One-touch One-touch
Power Supply Indoor Power Supply Indoor Power Supply
Power Supply Cord A 16 20
Thermostat ——
Protection Device — —
Dry Bulb Wet Bulb Dry Bulb Wet Bulb
Indoor Operation Range
Maximum 32 23 32 23
Minimum 16 11 16 11
Outdoor Operation Range
Maximum 55 31 55 31
Minimum 16 11 16 11
Model
Indoor CS-PC18KKF CS-PC24KKF
Outdoor CU-PC18KKF CU-PC24KKF