Page #10 background imageLoading...
Page #10 background image
10
Model
CS-RE9MKR
CU-RE9MKR
CS-RE12MKR
CU-RE12MKR
COOL HEAT
COOL
HEAT
Single,230V-240V,50Hz
Single,230V-240V,50Hz
Power/Current
[kW] 0.650-0.650 0.810-0.810
0.940-0.940 1.100-1.100
[A] 3.10-3.05 3.90-3.85
4.40-4.30 5.10-5.00
Refrigerant
[kg]
R410A
0.870
R410A
1.030
CoolingCapacity
[kW] 2.50-2.50
3.50-3.50
HeatingCapacity
[kW]
3.30-3.30 4.25-4.25
NoiseLevel
JISC9612[<70dB(A)]
[dB(A)]
42 42 42 42
Conditions1mDistance
Max. cooling
47 48 48 50
AirCirculation
[m
3
/min.]
13.8 13.8 13.8 14.1
ProductWeight
[kg]
8.5 8.5
24 28
Dimensions(H×W×D)
[mm]
290×848×204 290×848×204
540×780×289 540×780×289
Test conditions
1.
Temperature (°C)
Indoor Outdoor
*DBT *WBT *DBT *WBT
COOLING 27 19 35 24
HEATING 20 12 7 6
2. Standard piping length: 7.5 m (Includes Indoor Unit piping length).
3. Air lters are attached.
Indoor Unit
Outdoor Unit
PRODUCT SPECIFICATION
F568295_cover.indd 22 2011-8-4 16:40:20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-RE9MKR and is the answer not in the manual?

Panasonic CS-RE9MKR Specifications

General IconGeneral
BrandPanasonic
ModelCS-RE9MKR
CategoryAir Conditioner
LanguageEnglish

Related product manuals