EasyManuals Logo

Panasonic CS-S18MKQ Service Manual

Panasonic CS-S18MKQ
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #90 background imageLoading...
Page #90 background image
90
15.4.2 H12 (Indoor/Outdoor Capacity Rank Mismatched)
Malfunction Decision Conditions
During startup, error code appears when different types of indoor and outdoor units are interconnected.
Malfunction Caused
Wrong models interconnected.
Wrong indoor unit or outdoor unit PCBs mounted.
Indoor unit or outdoor unit PCBs defective.
Indoor-outdoor unit signal transmission error due to wrong wiring.
Indoor-outdoor unit signal transmission error due to breaking of wire 3 in the connection wires between the indoor
and outdoor units.
Troubleshooting

Table of Contents

Other manuals for Panasonic CS-S18MKQ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-S18MKQ and is the answer not in the manual?

Panasonic CS-S18MKQ Specifications

General IconGeneral
BrandPanasonic
ModelCS-S18MKQ
CategoryAir Conditioner
LanguageEnglish

Related product manuals