5
1. Cooling capacities are based on indoor temperature of 27qC D.B. (80.6qF D.B.), 19.0qC W.B. (66.2qF W.B.) and outdoor air
temperature of 35qC D.B. (95qF D.B.), 24qC W.B. (75.2qF W.B.)
2. Heating capacities are based on indoor temperature of 20qC D.B. (68qF D.B.) and outdoor air temperature of 7qC D.B. (44.6qF
D.B.), 6qC W.B. (42.8qF W.B.)
Note
• Specifications are subject to change without notice for further improvement.
Fan
Type Cross-Flow Fan Propeller Fan
Material ASG20K1 or ASG32K1 PP
Motor Type Transistor (8-pole) DC (8-pole)
Input Power W 30 —
Output Power W 30 40
Fan Speed
Lo (Cool/Heat) rpm 1100 / 1270 —
Me (Cool/Heat) rpm 1320 / 1450 —
Hi (Cool/Heat) rpm 1570 / 1630 870 / 850
SHi (Cool/Heat) rpm 1610 / 1630 —
Heat Exchanger
Fin Material Aluminium (Pre Coat) Aluminium
Fin Type Slit Fin Corrugated Fin
Row x Stage x FPI 2.1 x 11.4 x 23 2 x 24 x 17
Size (W x H x L) mm 640 x 304 x 25.4
36.4 x 504 x 713
684
Air Filter
Material Polypropelene —
Type One-Touch —
Item Unit
Power Source (Phase, Voltage, Cycle)
ø Single
V230
Hz 50
Input Power W
Cooling; 1.32k (160 ~ 1.6k)
Heating; 1.55k (160 ~ 2.08k)
Starting Current A 7.1
Running Current A
Cooling; 6.1
Heating; 7.1
Maximum current A 9.5
Power Factor %
Cooling; 94
Heating; 95
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core 3 (1.0mm)
Length m (ft) 1.5 (5)
Thermostat Electrical
Protection Device —
Annual Consumption kWh 660
ITEM UNIT INDOOR UNIT OUTDOOR UNIT