EasyManua.ls Logo

Panasonic CS-TZ25WKEW

Panasonic CS-TZ25WKEW
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
English
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature
°C (°F)
Indoor
Single split outdoor unit
*
1
Multi split outdoor unit *
2
DBT WBT DBT WBT DBT WBT
COOL
Max. 32 (89.6) 23 (73.4) 43 (109.4) 26 (78.8) 46 (114.8) 26 (78.8)
Min. 16 (60.8) 11 (51.8) -10 (14.0) - -10 (14.0) -
HEAT
Max. 30 (86.0) - 24 (75.2) 18 (64.4) 24 (75.2) 18 (64.4)
Min. 16 (60.8) - -15 (5.0) -16 (3.2) -15 (5.0) -16 (3.2)
Temperature
°C (°F)
Multi split outdoor unit
*
3
DBT WBT
COOL
Max. 43 (109.4) 26 (78.8)
Min. 16 (60.8) 11 (51.8)
HEAT
Max. 24 (75.2) 18 (64.4)
Min. -10 (14.0) -11 (12.2)
DBT: Dry bulb temperature, WBT: Wet bulb temperature
*
1
CU-TZ20WKE, CU-TZ25WKE, CU-TZ35WKE, CU-TZ42WKE, CU-TZ50WKE, CU-TZ60WKE, CU-TZ71WKE,
CU-RZ20WKE, CU-RZ25WKE, CU-RZ35WKE, CU-RZ50WKE
*
2
CU-2Z35TBE, CU-2Z41TBE, CU-2Z50TBE, CU-3Z52TBE, CU-3Z68TBE, CU-4Z68TBE, CU-4Z80TBE, CU-5Z90TBE
*
3
CU-2TZ41TBE, CU-2TZ50TBE, CU-3TZ52TBE
To learn more...
ACXF55-27151.indb 19ACXF55-27151.indb 19 12/2/2019 10:07:43 AM12/2/2019 10:07:43 AM