7
English
WARNING
This appliance is fi lled with 
R32 
(mild fl ammable refrigerant). 
If the refrigerant is leaked and 
exposed to an external ignition 
source, there is a risk of fi re.
Indoor unit and outdoor unit
The appliance shall be installed, and/
or operated in a room with fl oor area 
larger than Amin (m²) and keep away 
from ignition sources, such as heat/
sparks/open fl ame or hazardous 
areas such as gas appliances, 
gas cooking, reticulated gas 
supply systems or electric cooking 
appliances, etc.(Refer to Table A of 
Installation instructions table for Amin 
(m²))
Be aware that refrigerant may 
not contain an odour, highly 
recommended to ensure suitable 
fl ammable refrigerant gas detectors 
are present, operating and able to 
warn of a leak.
Keep any required ventilation 
openings clear of obstruction.
Do not pierce or burn as the 
appliance is pressurized. Do not 
expose the appliance to heat, fl ame, 
sparks, or other sources of ignition. 
Else it may explode and cause injury 
or death.
Precaution for using R32 
refrigerant
The basic installation work procedures are 
the same as conventional refrigerant (R410A, 
R22) models.
Since the working pressure is 
higher than that of refrigerant R22 
models, some of the piping and 
installation and service tools are 
special. Especially, when replacing 
a refrigerant R22 model with a 
new refrigerant R32 model, always 
replace the conventional piping and 
fl are nuts with the R32 and R410A 
piping and fl are nuts on the outdoor 
unit side. 
For R32 and R410A, the same fl are 
nut on the outdoor unit side and pipe 
can be used.
The mixing of different refrigerants 
within a system is prohibited. Models 
that use refrigerant R32 and R410A 
have a different charging port thread 
diameter to prevent erroneous 
charging with refrigerant R22 and for 
safety. 
Therefore, check beforehand. [The 
charging port thread diameter for R32 
and R410A is 1/2 inch.]
Must always ensure that foreign 
matter (oil, water, etc.) does not enter 
the piping. Also, when storing the 
piping, securely seal the opening by 
pinching, taping, etc. (Handling of 
R32 is similar to R410A.)
• 
Operation, maintenance, repairing 
and refrigerant recovery should be 
carried out by trained and certifi ed 
personnel in the use of fl ammable 
refrigerants and as recommended 
by the manufacturer. Any personnel 
conducting an operation, servicing 
or maintenance on a system or 
associated parts of the equipment 
should be trained and certifi ed.
 
Safety precautions