40
Recommended
length (mm)
abcd
35 35 35 55
Recommended
length (mm)
Ta p e
Connection cable
Indoor & outdoor
Connection cable
Escapement
Terminal
Board
Earth Wire longer
than others AC
wires for safety
reason
Outdoor unit
Indoor & outdoor
Connection cable
Holder
WARNING
This equipment must be properly earthed.
Note:
Secure the connection cable onto the control board with the holder.
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.
12.2.4.1 Wire Stripping and Connecting Requirement
WARNING
RISK OF FIRE
JOINING
OF WIRES
MAY CAUSE
OVERHEATING
AND FIRE.
Do not joint wires
OR
OR
Use complete wire without joining.
Use approved socket and plug with earth pin.
Wire connection in this area must follow to national
wiring rules.
Wire stripping
No loose strand
when inserted
10 ± 1 mm
5 mm or more
Indoor/outdoor
connection
terminal board
(gap between wires)
Conductor
fully inserted
Conductor over
inserted
Conductor not
fully inserted
ACCEPT PROHIBITED PROHIBITED
OR