ENGLISH
13
TROUBLESHOOTING
The following symptoms do not indicate malfunction.
SYMPTOM CAUSE
Mist emerges from indoor unit. Condensation effect due to cooling process.
Water owing sound during operation. Refrigerant ow inside the unit.
The room has a peculiar odour. This may due to damp smell emitted by the wall, carpet,
furniture or clothing.
Indoor fan stops occasionally during automatic fan speed
setting.
This helps to remove the surrounding odours.
Operation is delayed a few minutes after restart. The delay is a protection to the unit’s compressor.
Outdoor unit emits water/steam. Condensation or evaporation occurs on pipes.
The unit operates automatically when power is resumed
after a power failure.
It is the Auto Restart function of the unit. Operation will
be restarted automatically under the previous operation
mode and air ow direction when power is resumed as
the operation is not stopped by remote control.
Indoor fan stops occasionally during heating operation. To avoid unintended cooling effect.
Power indicator blinks before the unit is switched on. This is a preliminary step in preparation for the operation
when the ON timer has been set.
Cracking sound during operation. Changes of temperature cause the expansion/
contraction of the unit.
Check the following before calling for servicing.
SYMPTOM CHECK
Heating/Cooling operation is not working efciently. Set the temperature correctly.
Close all doors and windows.
Clean or replace the lters.
Clear any obstruction at the air inlet and air outlet vents.
Noisy during operation. Check if the unit has been installed at an incline.
Close the front panel properly.
Remote control does not work.
(Display is dim or transmission signal is weak.)
Insert the batteries correctly.
Replace weak batteries.
The unit does not work. Check if the circuit breaker is tripped.
Check if timers have been set.
The unit does not receive the signal from the remote
control.
Make sure the receiver not obstructed.
Certain uorescent lights may interfere with signal
transmitter. Please consult authorized dealer.
The unit stops and the timer indicator blinks.
Use remote control to retrieve error code.
CHECK
ERROR RESET RESET
SELECT
SET/CANCEL
QUIET
POWERFUL
/
A B
1
Press for 5
seconds.
3
Press for 5 seconds
to quit checking.
2
Press until you hear
beep sound, then jot
down the error code.
Note:
For certain error, you may
restart the unit with limited
operation with 4 beeps
during operation starts.
4
Turn the unit off and reveal the error code to authorized dealer.
PH005430 F567943.indb 13 2011-2-23 13:27:38

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-YE9MKX and is the answer not in the manual?

Panasonic CS-YE9MKX Specifications

General IconGeneral
Indoor unit typeWall-mountable
Indoor unit weight8000 g
Indoor units quantity1
Cooling airflow (indoor unit)750 m³/h
Heating airflow (indoor unit)780 m³/h
Indoor unit dimensions (WxDxH)803 x 214 x 283 mm
Indoor unit noise level (high speed)56 dB
Built-in displayNo
Remotely operatedYes
Cooling capacity (max)2150 BTU/h
Dehumidifying capacity1.4 l/h
Heating capacity (max)2750 BTU/h
Air conditioner functionscooling, heating
Cooling capacity in watts (max)2500 W
Heating capacity in watts (max)3200 W
Cooling energy efficiency (EER, W/W)3.28
Heating energy efficiency (COP, W/W)3.63
Outdoor units quantity0
Noise level (low speed)22 dB
Noise level (high speed)40 dB
Noise level (medium speed)27 dB
Annual energy consumption380 kWh
Power consumption (cooling) (max)1000 W
Power consumption (cooling) (min)190 W
Power consumption (heating) (max)1200 W

Related product manuals