12.3.6 How to Take Out Front Grille
Please follow the steps below to take out front grille if
necessary such as when servicing.
1 Set the vertical airflow direction louvers to the
horizontal position.
2 Remove the 2 caps (1.0 ~ 1.75HP) or 3 caps
(2.0 ~ 2.5HP) on the front grille as shown in
the illustration at right.
3 And then remove the 3 (1.0 ~ 1.75HP) or
4 (2.0 ~ 2.5HP) mounting screws.
4 Pull the lower section of the front grille
towards you to remove the front grille.
When reinstalling the front grille, carry out
above step 2 - 3 in the reverse order.
Vane
(Move the
vane to
downward)
Screw
Front
grille
Cap
(only for 2.0HP ~ 2.5HP model)
12.3.7 Disposal of Outdoor Unit Drain Water
If a drain elbow is used, the unit should be placed
on a stand which is taller than 3 cm.
If the unit is used in an area where temperature
falls below 0°C for 2 or 3 days in succession, it is
recommended not to use a drain elbow, for the
drain water freezes and the fan will not rotate.
Hose
Install the hose at an angle so that the
water smoothly fl ows out.
Drain elbow
7
12.3.8 Eco Sensor
Do not hit or violently press the sensor. This can
lead to damage and malfunction.
Do not place large objects near the sensor and
keep heating units or humidifiers away from the
sensors detection area. This may lead to sensor
malfunction.
ECO SENSOR
12.3.9 Check the Drainage
Open front panel and remove air filters. (Drainage
checking can be carried out without removing the
front grille.)
Pour a glass of water into the drain tray-styrofoam.
Ensure that water flows out from drain hose of the
indoor unit.
Drain tray-styrofoam
12.3.10 Evaluation of the Performance
Operate the unit at cooling/heating operation
mode for fifteen minutes or more.
Measure the temperature of the intake and
discharge air.
Ensure the difference between the intake
temperature and the discharge is more than 8°C
during Cooling operation or more than 14°C
during Heating operation.