94
14.14.1.8 Setting Temperature and Fan Speed Shift
ECONAVI ; Detecting human presence and activity, the unit controls room temperature to save energy.
Mode
Human
Low activity Normal activity High activity Absent
COOL/DRY
Set
temperature
+1.0°C
+2.0°C
HEAT
-2.0 °C-2.0 °C
14.14.1.9 Rhythmic Temperature Wave Operation
To further maximize the energy saving during ECONAVI operates at low activity level.
Start condition
o The unit is operates in Cool or Dry mode under ECONAVI operation, and
o Human activity sensor detects low activity level continuously for 60 minutes, and
Stop condition
o Unit is off, or
o ECONAVI is off, or
o Human activity sensor detects high activity level or absent, or
Control contents
o When all start conditions complied, set temperature will shift accordingly as following:
ECONAVI ; Detecting human presence and activity, the unit controls room temperature to save energy.
Mode
Human
Low activity Normal activity High activity Absent
COOL/DRY
Set
temperature
+1.0°C
+2.0°C
HEAT
ECONAVI
Precise control of temperature during low activity to maximise energy saving.
Mode
Human
Low activity
COOL/DRY
Set
temperature
ECONAVI take advantage of the human nature that
human being takes time to feel the temperature rise
during low activity level; the unit adjusts temperature to
maximise energy saving without sacri
cing the comfort.
-2.0 °C-2.0 °C
www.ampair.co.uk | sales@ampair.co.uk