13
Model
Indoor CS-Z25UFEAW CS-Z35UFEAW
Outdoor CU-Z25UBEA CU-Z35UBEA
Weight Net (I/D / O/D) kg (lb) 13 (29) / 33 (73) 13 (29) / 35 (77)
Piping
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 9.52 (3/8) 6.35 (1/4) / 9.52 (3/8)
Standard length m (ft) 5.0 (16.4) 5.0 (16.4)
Length range (min – max) m (ft) 3 (9.8) ~ 20 (65.6) 3 (9.8) ~ 20 (65.6)
I/D & O/D Height different m (ft) 15.0 (49.2) 15.0 (49.2)
Additional Gas Amount g/m (oz/ft) 10 (0.1) 10 (0.1)
Length for Additional Gas m (ft) 7.5 (24.6) 7.5 (24.6)
Drain Hose
Inner Diameter mm 28.5 28.5
Length mm 270 270
Indoor Heat
Exchanger
Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat)
Fin Type Slit Fin Slit Fin
Row × Stage × FPI 2 × 17 × 21 2 × 17 × 21
Size (W × H × L) mm 554 × 357 × 25.4 554 × 357 × 25.4
Outdoor
Heat
Exchanger
Fin Material Aluminium Aluminium
Fin Type Corrugated Fin Corrugated Fin
Row × Stage × FPI 2 × 24 × 19 2 × 28 × 17
Size (W × H × L) mm 36.4 × 504 × 824.2:793.7 36.38 × 588 × 856.3:827.7
Air Filter
Material Polypropelene Polypropelene
Type One-touch One-touch
Power Supply Outdoor Outdoor
Power Supply Cord A Nil Nil
Thermostat Electronic Control Electronic Control
Protection Device Electronic Control Electronic Control
Dry Bulb Wet Bulb Dry Bulb Wet Bulb
Indoor
Operation
Range
Cooling
Maximum °C 32 23 32 23
Minimum °C 16 11 16 11
Heating
Maximum °C 30 – 30 –
Minimum °C 16 – 16 –
Outdoor
Operation
Range
Cooling
Maximum °C 43 26 43 26
Minimum °C -10 -10
Heating
Maximum °C 24 18 24 18
Minimum °C -15 -16 -15 -16
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C DRY BULB (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C.
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C.
5. Standby power consumption 10.0w (when switched OFF by remote control, except under self protection control).
6. Specifications are subjected to change without prior notice for further improvement.