Why my Panasonic CU-2Z41TBE Air Conditioner makes water flowing sound?
- HHannah RogersAug 26, 2025
If you hear a water flowing sound during the operation of your Panasonic Air Conditioner, it is due to the flow of refrigerant inside the unit.
Why my Panasonic CU-2Z41TBE Air Conditioner makes water flowing sound?
If you hear a water flowing sound during the operation of your Panasonic Air Conditioner, it is due to the flow of refrigerant inside the unit.
What to do if my Panasonic CU-2Z41TBE Air Conditioner unit does not work?
If your Panasonic Air Conditioner unit isn't working, first check if the circuit breaker has tripped. Also, verify if any timers have been set that might be preventing the unit from turning on.
What to do if my Panasonic CU-2Z41TBE's HEAT/COOL mode isn't working efficiently?
If your Panasonic Air Conditioner isn't heating or cooling efficiently, make sure that you set the temperature correctly, close all doors and windows, clean or replace the filters, and clear any obstructions at the air inlet and outlet vents. Also, check if the circuit breaker has tripped or if any timers have been set.
Why does my Panasonic CU-2Z41TBE Air Conditioner's outdoor unit emit water or steam?
The water or steam emitted from the outdoor unit of your Panasonic Air Conditioner is due to condensation or evaporation occurring on the pipes.
Why is my Panasonic CU-2Z41TBE remote control not working?
If the remote control for your Panasonic Air Conditioner isn't working properly, with a dim display or weak signal, try these steps: 1. Ensure the batteries are inserted correctly. 2. Replace weak batteries with new ones.
What to do if Panasonic Air Conditioner doesn't receive signal from remote control?
If your Panasonic Air Conditioner isn't receiving the signal from the remote control: * Ensure that the receiver is not obstructed. * Be aware that certain fluorescent lights may interfere with the signal transmitter.
What to do if Panasonic Air Conditioner remote control does not work?
If the remote control for your Panasonic Air Conditioner isn't working, first ensure that the batteries are inserted correctly. If the display is dim or the transmission signal is weak, try replacing the batteries.
Why is the TIMER indicator always on on my Panasonic CU-2Z41TBE Air Conditioner?
If the TIMER indicator on your Panasonic Air Conditioner is always on, it means the timer setting repeats daily once set.
What to do if my Panasonic CU-2Z41TBE Air Conditioner doesn't receive the remote control signal?
If the Panasonic Air Conditioner unit does not receive the signal from the remote control, ensure that the receiver is not obstructed. Note that certain fluorescent lights may interfere with the signal transmitter; consult an authorised dealer.
Why does my Panasonic CU-2Z41TBE outdoor unit emit water/steam?
If your Panasonic Air Conditioner's outdoor unit emits water or steam, it's likely due to condensation or evaporation occurring on the pipes.
Cooling Capacity | 4.1 kW |
---|---|
Power Supply | 220-240 V, 50 Hz |
Refrigerant | R32 |
Operating Range Cooling | -10°C to 46°C |
Operating Range Heating | -15°C to 24°C |
Read instructions thoroughly for future reference. Keep Installation Instructions for installer.
WARNING for death/serious injury, CAUTION for injury/property damage. Understand safety symbols.
Appliance use by children requires supervision. Do not install in flammable atmosphere.
Use correct cords, do not share outlets, avoid wet hands, do not bend cord. Ground equipment.
Appliance uses R32 (flammable refrigerant). Risk of fire if leaked near ignition source.
Install in minimum room area. Keep away from ignition sources. Ensure ventilation is clear.
Higher pressure than R22/R410A. Replace piping/flare nuts. Do not mix refrigerants.
Locate circuit/piping away from heat sources. Regularly check alarms and ventilation.
Requires knowledge of flammable refrigerants, handling skills, and relevant legislation.
Protect pipe-work from damage. Comply with gas regulations. Ensure accessible connections.
System inspected by trained personnel. Ensure refrigerant charge and no leaks. Work with controlled procedures.
Minimize flammable gas risk. Avoid confined spaces. Wear protective equipment. Keep ignition sources away.
Check area with detector. Use suitable equipment. Ventilate if leakage occurs.
No ignition sources during work. Do not smoke. Survey area for hazards before work.
Check electrical components, refrigerant charge, ventilation. Ensure markings are legible.
Disconnect power for repairs. Use leak detection. Check cabling for wear and environmental effects.
Use appropriate leak detection methods. Avoid naked flames for detection.
Recover refrigerant, purge with inert gas, evacuate. Use OFN for purging.
Prevent contamination, use short hoses, earth system, label system. Avoid overfilling.
Familiarize with equipment, isolate electrically, ensure handling equipment, PPE, supervision.
Recover refrigerant safely using appropriate cylinders. Ensure correct number of cylinders.
Use remote to retrieve error codes. Write down code and consult dealer.
Table of diagnostic codes (Hxx, Fxx) and their corresponding abnormalities/protections.