36
11.2.4 Connect the Cable to the Indoor Unit
1. The inside and outside connection cable can
be co
nnected without removing the front grille.
2.
Unscrew the conduit cove
r and fix the conduit
connector to conduit cover with lock nut, then
se
cure it against chassi
s.
3.
Connection cable between indoor un
it and
outdoo
r unit should be UL listed or
CSA
approved 4 condu
ctor wires minimum AWG1
6
in accordan
ce with local electric code
s.
4.
Connection cable between indoor un
it and
outdoor unit should be UL listed or CSA
approved 4 condu
ctor wires minimum AWG1
6
in accordan
ce with local electric code
s.
o Ensure the colour of wires of outdoor unit
and termi
nal number are the same as t
he
indoo
r's repec
tively.
o Earth lead wire shall be Yellow/Green
(Y/G) in colou
r and shall be longer than
other lead wires as shown in the figure fo
r
electrical safety in case of the slipping.
Rear view for left piping installation
Drain cap
Drain hose
Adjust the piping slightly downwards.
Drain hose
Connection
cable
•
How to pull the piping and drain hose out, in case of embedded piping.
PVC tube
for drain
hose
Indoor unit
3
15
/16"(100mm)
Piping
Cable
Apply p utty or
caulking material
to s e al the wall
opening.
Connection
cable
Piping
M
o
r
e
t
h
a
n
18
1
/
2
"
(
4
7
0
m
m
)
M
ore
t
ha
n
3
7
1
3
/
3
2
"
(95
0
m
m
)
PVC tube (VP-65) for piping
and connection cable
PVC tube for drain hose (VP-30)
PVC tube for
drain hose (VP-20)
More than 27
9
/16"
(700 mm)
•
How to insert the connection cable and drain hose
inthecaseofleftpiping.
Cable
4
5
°
Drain
hose
Piping
Drain hose
from main unit
(For right piping, follow the same procedure)
Sleeve for piping ho le
Drain hose
Piping
Connection
cable
More than 37
13
/32"
(950 mm)
Replace the drain hose
Indoor unit
drain hose
3/4" (20 mm) nominal PVC pipe
- Install incline downward more than 1°
- Apply PVC glue at the join.
Drain hose adapter
9
Close join by Vinyl Tape ( )
•
Join indoor drain hose to 3/4" (20 mm) nomin al PVC pipe siz e
by using drain hose adapter
9
when necessary.
Drain hose adapter
9 usage
Remarks :
Make su re ind oor unit drain hose & 3/4" (20 mm ) nominal PV C pipe
are fully inserted to drain hose adapter
9
.
Terminals on the indoor unit 1 2 3
Colour of wires (connection cable)
Terminals on the outdoor unit 1 2 3
WARNING
This equipment must be properly earthed.
123
Earth Wire
longer than
others AC
wires for
safety
reason
Termi n a l
Board
Holder
Indoor and
outdoor
connection
cable
Chassis
Conduit
Connector
Conduit
Cover
Lock Nut
Rear Side of Indoor Unit