EasyManua.ls Logo

Panasonic CU-E9GKE - Sensible Capacity Charts

Panasonic CU-E9GKE
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
67
16.2. Sensible Capacity Chart
O CS-E7GKEW CU-E7GKE
O CS-E9GKEW CU-E9GKE
O CS-E12GKEW CU-E12GKE
230V Outdoor Temp. (°C)
Indoor wet
bulb temp.
30 35 40 46
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 2.03 1.54 0.44 1.90 1.48 0.47 1.77 1.42 0.51 1.61 1.35 0.55
19.0°C 2.05 0.48
19.5°C 2.23 1.61 0.45 2.09 1.55 0.48 1.94 1.49 0.52 1.77 1.42 0.56
22.0°C 2.43 1.67 0.46 2.27 1.61 0.49 2.12 1.55 0.52 1.92 1.48 0.57
230V Outdoor Temp. (°C)
Indoor wet
bulb temp.
30 35 40 46
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 2.58 1.96 0.54 2.41 1.88 0.58 2.24 1.80 0.62 2.04 1.71 0.67
19.0°C 2.60 0.59
19.5°C 2.83 2.05 0.55 2.65 1.97 0.59 2.46 1.89 0.63 2.24 1.80 0.68
22.0°C 3.09 2.12 0.56 2.88 2.04 0.60 2.68 1.97 0.64 2.44 1.88 0.70
230V Outdoor Temp. (°C)
Indoor wet
bulb temp.
30 35 40 46
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 3.47 2.63 0.87 3.24 2.52 0.94 3.02 2.43 1.00 2.74 2.30 1.08
19.0°C 3.50 0.95
19.5°C 3.81 2.76 0.89 3.56 2.65 0.95 3.31 2.55 1.02 3.01 2.43 1.10
22.0°C 4.15 2.86 0.90 3.88 2.75 0.97 3.61 2.65 1.04 3.28 2.53 1.12
TC
SHC
IP
-
-
-
Total Cooling Capacity (kW)
Sensible Heat Capacity (kW)
Input Power (kW)
Indoor 27°C/19°C
Outdoor 35°C/24°C

Table of Contents

Related product manuals