18
Indoor
Model CS-RZ50TKR
POS (EAN) 5025232871360
Outdoor
Model CU-RZ50TKR
POS (EAN) 5025232871551
Dimension
Unit
Height (ID / OD) mm (inch) 302 (11-29/32) / 619 (24-3/8)
Width (ID / OD) mm (inch) 1102 (43-13/32) / 824 (32-15/32)
Depth (ID / OD) mm (inch) 244 (9-5/8) / 299 (11-25/32)
PCKG.
(Stacking
Condition)
Height (ID / OD) mm (inch) 290 (11-7/16) / 680 (26-25/32)
Width (ID / OD) mm (inch) 1172 (46-5/32) / 958 (37-23/32)
Depth (ID / OD) mm (inch) 378 (14-29/32) / 416 (16-13/32)
Weight
Net (I/D / O/D) kg (lb) 12 (26) / 35 (77)
Gross (I/D / O/D) kg (lb) 14 (31) / 37 (82)
Stacking No. (CS / CU / CZ) Actual Stacking Quantity (12 / 6 / -)
Piping
Pipe Diameter (Liquid / Gas) mm (inch 6.35 (1/4) / 12.70 (1/2)
Standard Length m (ft) 5.0 (16.4)
Length Range ( min - max) m (ft) 3 (9.8) ~ 30 (98.4)
I/D & O/D Height Different m (ft) 15 (49.2)
Additional Gas Amount g/m (oz/ft) 15 (0.2)
Length for Additional (Gas) m (ft) 10 (32.8)
Drain Hose
Inner Diameter mm 16.7
Length mm 650
Indoor Heat
Exchanger
Fin Material Aluminium (Pre Coat)
Fin Type Slit Fin
Row x Stage x FPI 2 x 17 x 17
Size ( W x H x L) mm 836.5 x 357 x 25.4
Outdoor Heat
Exchanger
Fin Material Aluminium (Blue Coat)
Fin Type Corrugated Fin
Row x Stage x FPI 2 x 28 x 17
Size ( W x H x L) mm 36.4 x 588 x 781.3:752.7
Air Filter
Material Polypropelene
Type One-Touch
Power Supply Outdoor Power Supply
Power Supply Cord NIL
Thermostat Electronic Control
Protection Device Electronic Control
Dry Bulb Wet Bulb
Indoor Operation Range
Cooling
Maximum °C (°F) 32 (89.6) 23 (73.4)
Minimum °C (°F) 16 (60.8) 11 (51.8)
Heating
Maximum °C (°F) 30 (86.0) -
Minimum °C (°F) 16 (60.8) -
Outdoor Operation Range
Cooling
Maximum °C (°F) 46 (114.8) 26 (78.8)
Minimum °C (°F) 5 (41.0) -
Heating
Maximum °C (°F) 24 (75.2) 18 (64.4)
Minimum °C (°F) -15 (5.0) -
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
3. Specifications are subjected to change without prior notice for further improvement.