Model
CS-YE9MK
X
CU-YE9MK
X
CS-YE12MKX
CU-YE12MKX
CS-YE18MKX
CU-YE18MKX
COOL HEAT COOL HEAT COOL HEAT
Single, 230V,50Hz Single, 230V,50Hz Single, 230V,50Hz
Power/Current
[kW] 0.760 0.880 1.020 1.105 1.660 1.615
[A] 3.60 4.10 4.90 5.20 7.90 7.70
Refrigerant
[k
g
]
R410A
0.780
R410A
0.880
R410A
1.15
Cooling Capacity
[kW] 2.50 3.30 5.00
Heating Capacity
[kW] 3.20 4.00 5.50
Noise Level
JIS C 9612
[<70 dB(A)]
[dB(A)]
40 40 42 42 46 46
Conditions
1m Distance
Max. cooling/
heating
operation
47 48 48 50 50 52
Sound power
level
[dB(A)]
56 56 58 58 62 62
63 64 64 66 66 68
Air Circulation
[m
3
/min.] 12.5 13.0 13.5 13.9 14.6 15.3
kg
Product Weight
[k
g
]
8.0 8.0 7.5
22 26.5 31.5
Dimensions (H x W x D)
[mm]
283 x 803 x 214 283 x 803 x 214 283 x 803 x 214
540 x 780 x 289 540 x 780 x 289 540 x 780 x 289
PRODUCT SPECIFICATION
Test conditions
1.
Temperature (°C)
Indoor Outdoor
*DBT *WBT *DBT *WBT
COOLING 27 19 35 24
HEATING 20 12 7 6
2. Standard piping length: 7.5 m (Includes Indoor Unit piping length).
PH005430 F567943.indb 56 2011-2-23 13:27:32