Why does my room have a peculiar odor when using Panasonic CU-Z35UBEA?
- JJenny BennettSep 7, 2025
A peculiar odor in the room with your Panasonic Air Conditioner may be due to a damp smell emitted by the wall, carpet, furniture, or clothing.
Why does my room have a peculiar odor when using Panasonic CU-Z35UBEA?
A peculiar odor in the room with your Panasonic Air Conditioner may be due to a damp smell emitted by the wall, carpet, furniture, or clothing.
What to do if my Panasonic Air Conditioner unit does not work?
If your Panasonic Air Conditioner unit isn't working, first check if the circuit breaker has tripped. Also, verify if any timers have been set that might be preventing the unit from turning on.
Why is my Panasonic CU-Z35UBEA Air Conditioner remote control not working?
If the remote control for your Panasonic Air Conditioner isn't working properly, with a dim display or weak signal, try these steps: 1. Ensure the batteries are inserted correctly. 2. Replace weak batteries with new ones.
What to do if Panasonic CU-Z35UBEA doesn't receive signal from remote control?
If your Panasonic Air Conditioner isn't receiving the signal from the remote control: * Ensure that the receiver is not obstructed. * Be aware that certain fluorescent lights may interfere with the signal transmitter.
How to improve the efficiency of HEAT/COOL mode on my Panasonic CU-Z35UBEA?
To improve the efficiency of the HEAT/COOL mode on your Panasonic Air Conditioner: ensure the temperature is set correctly, close all doors and windows, and clear any obstructions from the air inlet and outlet vents.
How to improve HEAT/COOL mode efficiency on Panasonic CU-Z35UBEA?
To improve the efficiency of the HEAT/COOL mode on your Panasonic Air Conditioner: * Ensure the temperature is set correctly. * Close all doors and windows. * Clean or replace the filters. * Clear any obstructions at the air inlet and air outlet vents.
What to do if the switches or buttons on my Panasonic CU-Z35UBEA are not functioning properly?
If the switches or buttons on your Panasonic Air Conditioner are not functioning properly, turn off the power supply, unplug the unit, and consult an authorized dealer.
What to do if the Panasonic CU-Z35UBEA condenser is dusty?
If your Panasonic Air Conditioner's condenser is dusty and preventing heat radiation, you should clean the condenser.
Why does mist emerge from my Panasonic CU-Z35UBEA Air Conditioner indoor unit?
The mist emerging from the indoor unit of your Panasonic Air Conditioner is a condensation effect due to the cooling process.
Why does the indoor fan stop during heating on my Panasonic CU-Z35UBEA?
The indoor fan in your Panasonic Air Conditioner may stop occasionally during heating operation to avoid unintended cooling effect.
Cooling Capacity | 3.5 kW |
---|---|
Heating Capacity | 4.0 kW |
Energy Efficiency Class Cooling | A |
Energy Efficiency Class Heating | A |
Refrigerant | R32 |
Weight (Indoor Unit) | 8 kg |
Power Supply | 220-240 V, 50 Hz |
Noise Level (Outdoor) | 48 dB(A) |
Type | Split System |
Noise Level (Indoor) | 21 dB |
Specific safety guidelines for handling R32 refrigerant, including installation and pressure.
Procedures for checking refrigerant presence and handling leaks safely.
Requirement for fire extinguishing equipment during hot work.
Guidelines to prevent ignition sources during installation, repair, and disposal.
Ensuring adequate ventilation during operations involving refrigerant release.
Checks for refrigeration components, including electrical parts and charge size.
Safety procedures for repairing and maintaining electrical components.
Safety during repairs to sealed components, including electrical supply.
Guidelines for working on intrinsically safe components in flammable atmospheres.
Ensuring cabling is protected from wear, corrosion, and vibration.
Methods for detecting flammable refrigerants without ignition sources.
Acceptable methods for detecting leaks in refrigerant systems, including detector calibration.
Steps for safely removing and evacuating refrigerant from the system.
Requirements for safe refrigerant charging, including contamination prevention.