6 Wiring Diagram
6.1. Resistance of Fan Motor
windings and the rated
Capacitor
Model CW-XC100VK CW-XC120VK
Connection CWA951216 CWA951215
Blue - Yellow 34.6 34.8
Yellow - Brown 2.3 2.5
Brown - Orange 13.7 14.8
Red -Yellow 36.6 37.6
6.2. Resistance of Compressor
windings and the rated
Capacitor
Model CW-XC100VK CW-XC120VK
Connection CWB09623 CWB09624
C-R 0.690 0.724
C-S 2.429 2.168
Capacitor CWA312066 (40µF,
250VAC)
CWA312067 (45µ,
250VAC)
Note: Resistance at 20°C of Ambient Temperature.
7 Air Conditioner Performance Evaluation
Suction & Discharge Air
Temperature Difference
Current Determination Remedy
8°C and over (14.4°F) As specified. Nothing wrong. None.
8°C and over (14.4°F) Higher than specified. Nothing wrong, outdoor
temperature is too high, heat
radiation is not efficient.
Improve heat radiation.
Under 8°C (14.4°F) Higher than specified. Something is preventing heat
radiation.
Excessive amount of refrigerant.
Improve heat radiation.
Under 8°C (14.4°F) Lower than specified. Leakage of refrigerant or
refrigerant system is blocked.
Locate and repair leak.
Flush refrigeration cycle.
Under 8°C (14.4°F) Higher than specified by
50%.
Compressor defect. Replace the compressor.
Note: Room air humidity is relatively higher, the temperature difference will be smaller.