8
3-3 Mounting to mounting spacer (Optional)
(Front sensing type)
MS-EX20-FS
Mounting method
1. Fit the mounting spacer on the sensor.
2. Align the mounting holes of the mounting spac-
er and the sensor and mount with M3 screws.
The tightening torque should be 0.5N·m or less.
Mounting spacer
MS-EX20-FS
(Optional)
M3 screws