High−level Instructions
3 − 786
Outline Changing the file register bank number.
Program example
Boolean
Ladder Diagram
Address Instruction
n
Trigger
F415 CBFL, DT 110
X10
10
11
ST X 10
F415 (CBFL)
DT 1
n Constant data or area where register bank number is stored.
Operands
O
erand
Relay Timer/Counter Register
Index
register
Constant
Index
WX WY WR WL SV EV DT LD FL I K H f
modifier device
n A A A A A A A A A A A A N/A A N/A
Description
This instruction selects the current file register bank number.
At this time, the current file bank number is stored in the push area (the push area has only one effective level,
thus previous data is overwritten).
File register bank number: 0 to 2.
Precautions during programming
The file register bank is set to bank 0 at the first step of program.
The file register bank is also set to bank 0 at the first step of No. 2 program.
Special data register for file register bank.
DT90263
File register bank (current value) The current value o
ile register bank is stored.
DT90264
File register bank (shelter number) The shelter number of file register bank is stored.
Flag conditions
・Error flag (R9007): Turns on and stays on when:
・Error flag (R9008): Turns on for an instant when:
− The area specified using the index modifier exceeds the limit.
− The bank number is not from K0 to K2.
F415
P415
(PCBFL)
(CBFL)
Changing the file register bank number
vailable
N/A: Not Available