5-41
FP-e (A: Available, N/A: Not available)
Register
No.
Name Descriptions
Read
-ing
Writ
-ing
DT9059
Serial
communication
error code
Error code is sotred here when a
communication error occurs.
A N/A
DT9060
Step ladder process
(0 to 15)
DT9061
Step ladder process
(16 to 31)
DT9062
Step ladder process
(32 to 47)
DT9063
Step ladder process
(48 to 63)
DT9064
Step ladder process
(64 to 79)
DT9065
Step ladder process
(80 to 95)
DT9066
Step ladder process
(96 to 111)
DT9067
Step ladder process
(112 to 127)
Indicates the startup condition of the step ladder
process. When the process starts up, the bit
corresponding to the process number turns on.
Monitor using binary display.
A programming tool software can be used to
write data.
A A