Basic Instructions
2 117
Example 1 for setting periodical interrupt
Example:
ICTL, H2, K1500DF
S1
S2
[S1]: H0002
Specifies periodical interrupt (units: 10ms)
[S2]: K1500
Specifies the time interval for the periodical interrupt. With
K1500, the time interval is K1500 x 10ms = 15000ms (15s)
After this ICTL instruction is executed, the periodical interrupt
will occur every 15 seconds. At these times, the INT24
interrupt program will be executed.
INT24 program
Main program
15s 15s
Execution
ICTL instruction
Execution
Execution
To stop the periodical interrupt program, execute the following
program.
ICTL, H2, K0DF