High−level Instructions
3 − 55
Outline Exchanges the 16-bit blocked data.
For the FP0R/FPΣ/FP−X, the P type high−level instruction
“P18 (PBXCH)” is not available.
Program example
Ladder
Diagram
Boolean
Ladder Diagram
Address Instruction
D2 D3D1
Trigger
F18 BXCH, DT10, DT13, DT3110
R0
(DF)
10
11
12
ST R 0
F18 (BXCH)
DT 10
DT 13
DT 31
D1 Starting 16-bit area of block data 1
D2 Ending 16-bit area of block data 1
D3 Starting 16-bit area of block data 2
Operands
Operand
Relay Timer/Counter Register
Index
register
Constant
Inde
x
Inte
g
er
Operand
WX WY WR WL SV EV DT LD
FL
(*1)
I K H f
Index
modifier
Integer
device
D1 N/A A A A A A A A A A N/A N/A N/A A N/A
D2 N/A A A A A A A A A A N/A N/A N/A A N/A
D3 N/A A A A A A A A A A N/A N/A N/A A N/A
(*1) This cannot be used with the FP0R, FPΣ and FP−X.
F18
P18
16-bit blocked data exchange
(BXCH)
(PBXCH)
A
:
A
vailable
N/A: Not Available
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com