High−level Instructions
3 − 379
(1) Specifying word unit reception
If word unit reception is being used, the data for the specified number of words is sent from the memory area
of the remote station specified by S2 and N, and is stored in the memory area of the local station that starts
with D. If only the MEWNET−H network is being used, up to 1,020 words can be received at one time, and if
the network is using the MEWNET−P/W, up to 16 words can be received at one time.
15
Number of words received: H001 to H3FC (1 to 1020)
Specifies H0.
S1:
11 7 4 0
Example:
If 10 words of data are being received, K10(H000A) should be
specified in S1.
(2) Specifying bit unit reception
When data is being sent in bit units, the information for the specified bit of the memory area of the remote
station specified by S2 and N is stored in the specified bit of the memory area of the local station specified by
D.
1115
Bit No. of remote station: H0 to HF(0 to 15)
Specifies H8.
S1:
740
Specifies H0
Bit No. of local station: H0 to HF(0 to 15)
Example:
If the data from Bit No. 0 of the memory area in the remote
station is being sent to Bit No. 15 of the local station memory
area, H8F00 should be specified in S1.
(3) Specifying the remote station (common to both word/bit transmission)
15
Unit No.: H01 to H40 (0 to 64)
Specifies H0.
S1+1:
11 7 4 0
Route No.: H1 to H8(1 to 8)
The unit number should be converted to a hexadecimal number and specified.
− For MEWNET−W: H01 to H20 (1 to 32)
− For MEWNET−P: H01 to H3F (1 to 63)
− For MEWNET−H: H01 to H40 (1 to 64)