High−level Instructions
3 − 428
Outline Data is transmitted to external equipment via the COM port of the
specified MCU.
This function is available from FP2/FP2SH Ver. 1.50 or later.
Program example
Boolean
Ladder Diagram
Address Instruction
Trigger
S n
10
X4
F159 MTRN, DT 0, K 10, H C1
1
1
DF
D
10
11
12
ST X 4
DF
F159 (MTRN)
DT 0
K10
HC1
S Head area of the data table
n Area or constant data in which the byte number of the transmitted data stored
− When it is positive value, the terminal code is added in transmission.
− When it is negative value, the terminal code is not added in trasmission.
− In case of H8000, the application of the MCU port specified in transmission is
changed.
D Specification of the slot number and port number of the MCU unit which the
data is transmitted.
Operands
modifier
S A A A A A A A A A A N/A N/A A
n A A A A A A A A A A A A A
D N/A A A A A A A A A A A A A
(*1) I0 to ID.
Reference: FP2 Multi Communication Unit Manual
FP2/FP2SH
P159
(PMTRN)
Serial data communication
(for MCU COM port)
Availability
FP2/FP2SH
(MTRN)
F159
A: Available
N/A: Not Available