High−level Instructions
3 − 461
Outline When the elapsed value of the specified channel of the high−speed
counter matches the target value, the specified output is turned on.
Program example
Ladder
Diagram
Boolean
Ladder Diagram
Address Instruction
10
F166 HC1S , K 0 , K10000 , Y0
Trigger
R0
D
DF
S
n
10
11
12
ST R 0
DF
F166 (HC1S)
K0
K 10000
Y0
n
The channel number of the high−speed counter that corresponds to the match
output (FP0/FPΣ: H0 to H3, FP−X: H0 to HB).
S
The high−speed counter target value data or the starting address of the area
that contains the data.
D The output coil that is turned on when the values match (Yn).
Operands
Operand
Relay Timer/Counter Register
Index
register
Constant
Inde
x
Operand
WX WY WR SV EV DT
IX
(*1)
IY
(*2)
K H
Index
modifier
n N/A N/A N/A N/A N/A N/A N/A N/A A A N/A
S A A A A A A A N/A A A A
D N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
(*1) I0 to IC on FPΣ/FP−X/FP0R
(*2) ID on FPΣ/FP−X/FP0R
Explanation of example
Target value
10000
0
R0
Y0
Elapsed value
End of F166 control
(clear)
ON when matches target value
High−speed counter
control flag varies
Target value match on
(with channel specification)
F166
(HC1S)
Availability
FP0/FP0R/FP−e/
FPΣ/FP−X
A: Available
N/A: Not Available