High−level Instructions
3 − 513
Pulse output channels and areas used
Channel
No.
Output Output type
Position
control
starting
input
Pulse
output
instruction
flag
Elapsed
value area
Target
value
area
Correction
speed of
initial
speed
Deceleration
minimum
speed
Acceleration
forbidden
area starting
position
ch0
Y0 CW PLS
X0
DT90052
R9120
DT90400 DT90402
DT90406
DT90407
DT90408
ch0
Y1 CCW SIGN
DT
90052
bit6
R9120
DT90400
DT90401
DT9
04
02
DT90403
DT90406 DT90407
DT90408
DT90409
ch1
Y2 CW PLS
X1
DT90052
R9121
DT90410 DT90412
DT90416
DT90417
DT90418
ch1
Y3 CCW SIGN
DT
90052
bit6
R9121
DT90410
DT90411
DT9
04
12
DT90413
DT90416 DT90417
DT90418
DT90419
ch2
Y4 CW PLS
X2
DT90052
R9122
DT90420 DT90422
DT90426
DT90427
DT90428
ch2
Y5 CCW SIGN
DT
90052
bit6
R9122
DT90420
DT90421
DT9
04
22
DT90423
DT90426 DT90427
DT90428
DT90429
ch3
Y6 CW PLS
X3
DT90052
R9123
DT90430 DT90432
DT90436
DT90437
DT90438
ch3
Y7 CCW SIGN
DT
90052
bit6
R9123
DT90430
DT90431
DT9
04
32
DT90433
DT90436 DT90437
DT90438
DT90439
Setting the data table
S
S+1
Control code
S+2
S+3
Initial speed
(Hz)
V
elocit
y
ran
g
e
(
Fre
q
uenc
y)
(
Hz
)
S+4
S+5
Target speed
(Hz)
V
elocity
range
(Frequency)
(Hz)
1Hz to 50kHz [K1 to K50000 (Unit: Hz)]
S+6
S+7
Acceleration time
(ms)
Acceleration time up to the max. speed 50kHz.
Acceleration time range (ms) K1 to K32760 (Unit: ms)
S+8
Deceleration time
Deceleration time from the max. s
p
eed 50kHz.
S+8
S+9
Deceleration
time
(ms)
Deceleration
time
from
the
max
.
speed
50kHz
.
Deceleration time range (ms) K1 to K32760 (Unit: ms)
S+10
S+11
Target value
(No. of pulses)
Target value range
K−2,147,483,648 to K2,147,483,647
Note the following characteristics according to the specified initial speed.
(1) When the initial speed is 1 or higher, and lower than 46Hz, the control up to the maximum frequency to the
degree of 10kHz can be performed.
If the frequency is higher than that, the speed error will be larger.
(2) When the initial speed is 46 or higher, and lower than 184Hz, the control up to 50kHz can be performed.
(3) When the initial speed is 184 or higher, the control up to 50kHz can be performed.
The speed error around 50kHz will be smallest.
Change of speed during pulse output
(1) If the target value is set to a value larger than 50kHz, it will be corrected to 50kHz.
(2) If the elapsed value crosses over the acceleration forbidden area starting position during accelerating,
acceleration cannot be performed.
For information on the acceleration forbidden area starting position, refer to the special registers.
(3) For deceleration, the speed cannot be lower than the deceleration minimum speed.
For information on the deceleration minimum speed, refer to the special registers.