High−level Instructions
3 − 631
Outline These instructions write a specified number of characters from a
character string to a specified position in the character string.
With the FP0R/FPΣ/FP−X, the differential execution type instruction P264 (PMIDW)
cannot be specified.
Program example
Boolean
Ladder Diagram
Address Instruction
10
F264 MIDW, DT0,K3,DT20,K1
S1
Trigger
R10
D
S2
n
10
11
ST R 10
F264 (MIDW)
DT 0
K3
DT 20
K1
S1 Character string
S2 Area in which the character string position is stored, or constant data
D Starting address of the area in which the character string is stored
n Area in which the position of the character string is stored, or constant data
Operands
Relay Timer/Counter Register
Index
register
Constant
Inde
Operand
WX WY WR WL SV EV DT LD
FL
(*1)
I
(*2)
K H f M
modifier
S1 A A A A A A A A A A N/A N/A N/A A A
S2 A A A A A A A A A A A A N/A N/A A
D N/A A A A A A A A A A A N/A N/A N/A A
n A A A A A A A A A A A A N/A N/A A
(*1) Cannot be specified with FP0R, FPΣ and FP−X.
(*2) I0 to ID
F264
P264
(PMIDW)
(MIDW)
Writing a character string to a character string
A: Available
N/A: Not Available