High−level Instructions
3 − 690
Specifying the integer device with [D], the real numbers are automatically converted into integer data.
F313 F%, DT 0, DT 2, % DT 4
R0
When the constant K is specified in S1 and S2, the operations are the same as when a integer device is
specified.
Program example
The “f5.432100” is stored to DT30 and DT31 when the R0 turns on.
F312 F%, f54.321, f10, DT30
R0
Precaution during programming
For FP, this instruction F313 (F%) cannot be programmed in the interrupt program.
Flag conditions
・Error flag (R9007): Turns on and stays on when:
・Error flag (R9008): Turns on for an instant when:
− The area specified using the index modifier exceeds the limit.
− If data other than real number data is specified in “S1+1 and S1” and “S2+1
and S2.”
− If result of processing is outside integer range when integer device is
specified in D+1 and D.
− The real number data (floating point data) for the divisor specified by S2 is
“0.0”.
・Carry flag (R9009): Turns on for an instant when the result is overflowed.