High−level Instructions
3 − 709
Outline This instruction raises a floating point real number to the specified
power.
For the FP0R/FPΣ/FP−X/FP0/FP−e, the P type high−level instruction
“P323 (PPWR)” is not available.
Program example
Ladder
Diagram
Boolean
Ladder Diagram
Address Instruction
S1
Trigger
S2 D
F323 PWR, DT10, DT20, DT3010
R0
10
11
ST R 0
F323 (PWR)
DT 10
DT 20
DT 30
S1 Real number data (2 words) or lower 16-bit area of 32-bit data (for
multiplicand)
S2 Real number data (2 words) or lower 16-bit area of 32-bit data (for multiplier)
D Lower 16-bit area of 32-bit data (for result)
Operands
O
p
erand
Relay Timer/Counter Register
Index
register
Constant
Index
modifier
Integer
device
Operand
WX WY WR WL SV EV DT LD FL I K H f
modifier device
S1 A A A A A A A A A A A A A A* A
S2 A A A A A A A A A A A A A A* A
D N/A A A A A A A A A A N/A N/A N/A A A
* Index modification of a real number is not possible.
Description
The real number data specified by S1+1 and S1 is raised to the power specified by the real number data of
S2+1 and S2, and the result is stored in D+1 and D.
[S1+1, S] ^ [S2+1, S2] → [D+1, D]
Specifying the integer device with [S1] and [S2], the integer data is internally converted to real numbers
before operations continue.
F323 PWR, % DT 0, % DT 2, DT 4
R0
F323
P323
(PPWR)
(PWR)
Floating point data power
A
:
A
vailable
N/A: Not Available