EasyManua.ls Logo

Panasonic KX-TG4771B - RF Check Flowchart; RF Performance Verification

Panasonic KX-TG4771B
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38
KX-TG4771B/KX-TG4772B/KX-TG4773B/KX-TGA470B
10.1.6.2. RF Check Flowchart
Each item (1 ~ 5) of RF Check Flowchart corresponds to Check Table for RF part (P.39).
Please refer to the each item.
Note:
(*1) Refer to Check Link (P.35).
Start
Link
confirmation
Normal
1
Control
signal
confirmation
X'tal
Frequency
confirmation
TX confirmation
Range
confirmation
Normal
TEST RANGE Check.
Check BBIC interface parts.
(RF Block <->BBIC on BU/HS P.C.B)
Adjust X'tal Frequency. (*1)
Check TX Block.
GOOD
5
2
3
4
OK
OK
OK
NG
NG
NG
NG
NG
OK
OK

Table of Contents

Related product manuals