Digital Laser Sensor LS-400 SERIES
Easy setting, dual display
Equipped with 2 large 4-digit digital displays. While checking the current incident light intensity (red display), the
optimal threshold value (green display) can be set easily.
10 mm 0.394 in
thickness
Large jog switchThreshold value setting display
Green LED, 4 digits (Max. display: 9999)
Current incident light intensity display
Red LED, 4 digits (Max. display: 9999)
Large MODE key
2 switches enable simple operation
Only two switches, the large MODE key and the large jog switch, are required for operation.
Pressing the switch
selects or cancels the
Moving the switch from
side to side allows items
confirms the selected
Threshold tracking function saves
maintenance time
This function seeks
changes in the light emitting
amount resulting from
changes in the environment
over long periods (such
as dust levels), so that
the incident light intensity
can be checked at desired
intervals and the threshold
values can be reset
automatically. This helps to
reduce the man-hours for
maintenance.
Time
Current value
The amount of light
received when there
is no object
Incident light intensity
Threshold value
Digital fiber sensor
FX-500/300 series
Digital pressure sensor
DPS-400 series
Up to 16 units can be
connected together
Note: Because the transmission method varies depending on the
amplifiers, check the instruction manual for the amplifiers when
connecting them.
Wiring and space saving
The quick-connection cables enable reductions in wiring.
(connector type)
The connections and man-hours for the relay terminal
setup can be reduced and valuable space is saved.
Also, LS-400 series ampliers can of course be
connected side-by-side with a connector type amplier
of FX-500/300 series digital ber sensors or DPS-400
series digital pressure sensors.
Note: Because the transmission method varies depending on the
ampliers, check the instruction manual for the ampliers when
connecting them.
*
CC-Link and CC-Link IE Field are a registered trademark of
Mitsubishi Electric Corporation.
DeviceNet is a registered trademark of ODVA (Open DeviceNet
Vender Association, Inc.).
EtherCAT is a registered trademark of Beckhoff Automation GmbH.
New release of type with upper communication functions to facilitate preventive maintenance!
LS-403
Network communication possible
Can connect to Open Network CC-Link IE Field /
CC-Link / DeviceNet / EtherCAT via Communication
Unit for Open Network SC-GU3 series. Monitoring and
various settings can be done from PLC, PC, etc.
しきい
1ch
現在値
90 65
2ch 50 0
3ch 40 70
4ch 0 0
5ch 0 0
6ch 0 0
7ch 0 0
8ch 0 0
しきい
9ch
現在値
0 0
10ch 0 0
11ch 0 0
12ch 0 0
13ch 0 0
14ch 0 0
15ch 0 0
16ch 0 0
LS
-
403/501
FX
-
501/502
FX
-
301/305
DPS
-
401/402
Current values
of connected
sensors are
shown.
[Touch panel display example]
Threshold values of
connected sensors are
shown.
End unit
Digital laser sensor
Digital fiber sensor
Digital fiber sensor
Digital pressure sensor
Communication Unit
for Open Network
SC-GU3
series