7.4.7. Simple Resolution Real Time Adjustment
Rotate the three adjustment pins while monitoring bar graphic indicators. See details in below.
7.4.6.1 Procedure of Simple Resolution Real Time Adjustment
As for Adjustment conditions/procedure, consult the "Operating Instructions" which is available in software package.
The 1st Lens Frame Unit is adjustment available in real time.
Click “Real-Time Measurement.
The chart appears in real time on the screen.
*If no picture of the chart appears, do attempt to
change “DeviceNum” to 0, 1 or 2.
Green frames indicate the suitable point for measurement.
(they can be widened or narrowed)
Adjust three pins so that the all bar indicators go into OK(green).
If the bar graphic indicators do not obtain the OK(green), make sure
of setting & measurement environment and attempt adjustment.
Torx driver (RFKZ0609)
Adjustment Pin
1st Lens Frame Unit
Peel off the glue around the pins
so that adjustment can be conducted.
The adjustment of pins must be done
while the screws are slightly loosened.
(5.5Ncm±0.5Ncm)
Part No:
SUKZ000071(*)
(*) The new jig is optimized for workability.
If unavailable, use a flathead screwdriver instead.
①
②
③
④
Graphic indicator
Numerical value
④
Please rotate them little by little.
(30~45 degree)
33