EasyManua.ls Logo

Panasonic MC-CG475-BE7A - User Manual

Panasonic MC-CG475-BE7A
11 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
© 2007 Matsushita Electric Industrial Co., Ltd. All
rights reserved. Unauthorized copying and distribu-
tion is a violation of law.
Order No VCB0703005CE
Vacuum Cleaner
MC-CG475-BE7A
Product Color : Metalic blue
Destination : Germany
TABLE OF CONTENTS
PAGE PAGE
1 Specifications ----------------------------------------------------- 2
2 Location of Controls and Components ------------------- 3
3 Troubleshooting Guide----------------------------------------- 5
4 Disassembly and Assembly Instructions ---------------- 6
4.1. Dust box cover assembly removal -------------------- 6
4.2. Separate the upper and lower body units ----------- 6
4.3. Printed circuit board assembly (P.C.B Ass’y)
removal------------------------------------------------------- 7
4.4. Motor removal ---------------------------------------------- 9
4.5. Cord reel partition unit replacement -----------------10
4.6. Rail base U replacement -------------------------------10
4.7. Spring-loaded cord reel pre-winding-----------------10
4.8. How to disassemble the turbine nozzle ------------11
5 Wiring Connection Diagram ---------------------------------12
6 Exploded View and Replacement Parts List -----------13
6.1. EXPLODED VIEW (ATTACHMENTS) --------------13
6.2. PARTS LIST (ATTACHMENTS) ----------------------14
6.3. EXPLODED VIEW (BODY UNIT)-------------------- 15
6.4. PARTS LIST (BODY UNIT)---------------------------- 16
6.5. PACKING INSTRUCTIONS --------------------------- 17
6.6. PACKING LIST ------------------------------------------- 18

Questions and Answers

  • H
    Haley LewisAug 11, 2025
    What to do if my Panasonic MC-CG475-BE7A motor runs but there is no suction?
    • M
      molly89Aug 11, 2025
      If your Panasonic Vacuum Cleaner's motor is running but there's no suction, check for blockages and remove them. Also, inspect the dust bag; if it's full, replace it with a new one. Examine the secondary filter for clogs; if it's choked up, remove and clean it or replace it.
  • M
    Mary DavisAug 19, 2025
    How to fix a Panasonic MC-CG475-BE7A when the motor does not change power?
    • D
      dparsonsAug 19, 2025
      If the motor of your Panasonic Vacuum Cleaner always runs at full speed, and the resistance does not vary, replace the P.C.B. Ass'y. Also, if the components are short-circuited, replace the P.C.B. Ass'y.
  • S
    Samantha BrewerAug 26, 2025
    What to do if my Panasonic Vacuum Cleaner motor runs irregularly?
    • H
      Holly BrownAug 26, 2025
      If your Panasonic Vacuum Cleaner motor runs irregularly, replace P.C.B. Ass’y.
  • A
    Austin BanksSep 3, 2025
    How to troubleshoot a Panasonic MC-CG475-BE7A Vacuum Cleaner when the motor fails to rotate?
    • B
      Brandi MayerSep 3, 2025
      If the motor of your Panasonic Vacuum Cleaner fails to rotate, and there is no continuity, replace the cord reel partition unit. Also, if there is no continuity, replace P.C.B. Ass’y. In addition, if there is no continuity, replace the motor. Finally, if it has any problem or if anything unusual is found, replace the P.C.B. Ass’y.