E15
--
E14
-
English
Conformance to EC directive and UL standard/ Specications
EC Directives
The EC directives apply to all such electronic products as those having specic functions 
and directly sold to general consumers in EU countries.  These products are required to 
meet the EU unied standards and to be furnished with CE marking.
Our brushless motor and amplier meet the EC Directives for Low Voltage Equipment so 
that the machine or equipment comprising our brushless motor and amplifier can meet 
relevant EC Directives.
EMC Directives
Our brushless motor can meet EMC Directives and related standards.  However, to meet 
these  requirements,  the  systems  must  be  limited  with  respect  to conguration  and  other 
aspects, e.g. the installation and some special wiring conditions must be met.  This means 
that in some cases machines and equipment comprising our brushless systems may 
not satisfy the requirements for wiring and grounding conditions specified by the EMC 
Directives.  Therefore, conformance to the EMC Directives (especially the requirements for 
emission noise and noise terminal voltage) should be examined based on the nal products 
that include our system.
Applicable standard
Applicable standard
UL
UL1004  Standard for electric motor
CSA
(c-UL)
C22.2 No.100  Standard for electric motor
CE
EN60034-1  Standard for rotary electric machine (low voltage directive)
EN60034-5  Standard for rotary electric machine (low voltage directive)
CCC
GB12350  Safety standard for low-power electric motor
Conguration of peripheral equipment
Power 
supply
・
 100 V system: Single phase 100 V to 120 V ± 10%, 50/60 Hz
  200 V system: Single phase 200 V to 240 V ± 10%, 50/60 Hz
・
 Use the equipment under the environment of overvoltage category II specied by 
IEC60664-1.
  In order to obtain overvoltage category III, insert a transformer conforming to EN 
standard or IEC standard to the input of brushless amplier.
・
 Use an electric wire size suitable to EN60204-1.
Circuit 
breaker
Fuse
Be sure to connect a specied no-fuse breaker certied by IEC standard or UL, or 
a fuse certied by UL between power supply and noise lter. Meeting this condition 
allows conformance with UL508C (le No. E164620) and UL1004 (le No. E166557).
Noise
 lter
When installing one noise lter at the power supply for more than one brushless motor 
used, contact the manufacturer of noise lter. 
Surge 
absorber
Install a surge absorber on the primary side of noise lter. However, in performing 
the voltage resistance test of machine and equipment, be sure to remove the surge 
absorber; otherwise, the surge absorber may be ruptured.
Grounding
Be sure to connect the grounding Terminal of brushless amplier and protective 
grounding wire (PE) of system for preventing electric shock. Do not tighten the 
grounding wires together but connect them individually. 
Conformance to EC directive and UL standard
Wiring of peripheral equipment
Specications
• General specication
Model name
Rated 
output 
(W)
Power input
Motor
Rated
Current
(A)
Rated 
torque 
(N
・
m)
Starting
torque 
(N
・
m)
Rated 
rotation 
speed 
(r/min)
  Brushless 
*
motor
  Brushless 
*
amplier
Voltage
(V)
Tolerance
(%)
Frequency
(Hz)
Rated 
input 
current
(A)
MBMU5AZA
*
MBEG5A1BC
*
50
Single phase
100 to 120
±10
50/60
1.5 0.53
0.16 0.24
3000
MBMU5AZA
*
MBEG5A5BC
*
Single/3-phase
200 to 240
0.7 0.53
MBMU9A1A
*
MBEG9A1BC
*
90
Single phase
100 to 120
2.2 1.0
0.29 0.43
MBMU9A2A
*
MBEG9A5BC
*
Single/3-phase
200 to 240
1.1 0.5
MBMU1E1A
*
MBEG1E1BC
*
130
Single phase
100 to 120
2.8 1.3
0.41 0.62
MBMU1E2A
*
MBEG1E5BC
*
Single/3-phase
200 to 240
1.5 0.72
*
 The “
*
” in the motor designation is replaced with the symbol indicating the shaft specication.
*
 The “
*
” in the amplier designation is replaced with the character V indicating GV series or 
  P indicating GP series.
• Never use a GP series amplier in combination with a GV series motor. 
  A wrong combination will cause malfunction.
• Common specication
Item Specications
Brushless motor
MBMU5AZA
*
MBMU9A
*
A
*
MBMU1E
*
A
*
Brushless amplier
MBEG5A
*
BC
*
MBEG9A
*
BC
*
MBEG1E
*
BC
*
Rated output (W) 50 90 130
Rated speed 3000 r/min
Speed control range 30 to 4000 r/min (Speed ratio 1:133)
Motor heat resistance class 130(B)  (UL certied 105 (A))
Time rating Continuous
Motor mass (kg)
(
0.7
) (
1.0
) (
1.2
)
Molded Case
Circuit Breaker
(MCCB)
or Fuse
Brushless
amplifier
Brushless
motor
Surge 
absorber
Noise filter
Protection ground
(PE)
ground
Power
supply
Ferrite core (Noise filter for signal line)
option DV0P1460 (*Qty.:
4 ) (part No.: ZCAT3035-1330/TDK Corp.)
* The ferrite core should insert one 
  or more pieces in an electric wire, 
  respectively.