Control of starting
FC fan motor is rotated of high speed, for 10 seconds after starting.
Synchronous control of compressor
FC fan is operated, while compressor is operated.
FC fan is operated, while FC Cooling Mode.
Control of Door Open/Close
FC fan is stopped while FC door is opened.
FC fan delay control, when FC defrost is stopped
When Defrost ends, three minutes pass after compressor works, the FC fan does the forcibly stop for six minutes.
Control of FC Fan rotational speed
High speed drive: DC 12V
Common drive: DC 10V
Stop: 0V
5.7. Compressor Rotational Speed Control
For securing the amount of cooling according to the overload at a high ambient temperature, the rotational
speed of the compressor is changed by difference of temperature between FCC and FC Control setting, PCC
and PC Control setting.
Detection : FCC, PCC, ATC sensor
5.7.1. Normal time
The judgment of compressor ON: FCC is ON temperature or above
or
PC and FC Cooling Mode
The judgment of compressor OFF: While FC is cooling FCC is OFF temperature OFF or above
While power is turning on of FC Defrost Heater,
While waiting of compressor start.
5.7.2. The use rotational speed
The rotational speed of compressor is changed by deference between FCC temperature standard value (ON tempera-
ture) and FCC temperature, PCC temperature standard value and PCC temperature.
The rotational speed according to ambient temperature is as follows, it doesn't drive in other rotational speeds.
The use rotational speed
The use rotational speed according to ambient temperature is as follows
In case Super Freeze
Ambient temperature is 21°C or below 43 / 59 r/s
Ambient temperature is 22°C or above, 33°C or below 59 / 71 r/s
Ambient temperature is 34°C or above 59 / 71 r/s
In case normal control
ATC correction temperature is
21°C or below
PC Cooling Mode Common
FC Cooling Mode Common
ATC correction temperature is
22°C or above, 28°C or below
PC Cooling Mode Low speed
FC Cooling Mode High speed
ATC correction temperature is
29°C or above, 33°C or below
PC Cooling Mode Low speed
FC Cooling Mode High speed
Setting rotational speed of compressor
Rotational speed R1 R2 R3 R4 R5
Setting value r/s 25 39 43 59 71
Ambient temperature Rotational speed of compressor
A 21°C or below 25/39/43 r/s
B 22°C to 28°C 25/39/43/59 r/s
C 29°C to 33°C 43/59/71 r/s
D 34°C or above 59/71 r/s