The figure of after Cover Coil FC Assy is removed
11.4.3. SENSOR DEFROST, TEMPER-
ATURE FUSE A’SSY RADIANT
HEATER
1. SENSOR DEFROST
a. Remove Holder Def Sensor that is installing upper
side of Accumulator.
b. Remove Sensor Defrost from Holder Def Sensor.
c. Pull Bag Joint from storage part of depths of
upper side of FC.
Cut Cable Tie of Bag Joint, then take out wires and
connectors inside it.
d. Remove the connector of Sensor Defrost, then
replace new Sensor Defrost.
NOTES ON INSTALLATION OF SENSOR DEFROST
Install Sensor Defrost in Holder Def Sensor, then install
Holder Def Sensor in upper side of Accumulator as
before.
Tighten Bag Joint that is put in the connector of Sensor
Defrost with other connectors by Cable Tie as before.
Store Bag Joint to the place as before.
2. TEMP FUSE A’SSY
a. Cut Cable Tie that is fixation of Temp Fuse A’ssy
in side of Evaporator.