33
3. After pulling the cover, flip it to the right side of the cabinet.
4. Take out the damper motor cables from the hook.
5. Remove the sealing material (putty).
Note: Keep sealing material for re-sealing the connectors after replacement.
6. Disconnect the dumper motor connector from housing and remove the multiflow cover.
Note: Damper motor is assembled in the multiflow cover.