5.2. FC Defrost Control
FC defrost control is performed with the internals of a definite period of time.
1. When Power Supply Is Turned On.
When power supply is turned on and 4 hours passes, FC defrost control begins.
If when the power supply is turned on, FCC temperature 25°C or above and add the condition, ATC correction
temperature 25°C or above, and 12 hours later FC defrost control begins.
2. Normal operation
ATC correction temperature 19°C or above.
13 hours later when the FC defrost control had done, it begins again.
ATC correction temperature 18°C or below.
28 hours later when the FC defrost control had done, it begins again.
3. End
FC defrost control ends when the DEF temperature 10°C or above from the last time operation had done.
5.3. PC Defrost Control
1. FC and PC Defrost simultaneous control.
PC defrost control begins the same time till FC defrost control begins.
PC defrost heater never turns off till FC defrost control ends.
2. PC defrost control (not FC defrost control is performed)
About 5.5 hours had passed after FC defrost control ends, PC defrost heater turns on the case, FC cooling mode or
compressor off mode.
The DFP reaches 2°C or above, PC defrost heater turns off. However PC defrost heater turns on at least 10 minutes.
PC defrost single control is not perform, before FC defrost control begins.
5.4. 3-Way Valve Control
Cooling Mode Change is controlled by detected temperature of PEC, FCC, PCC, SCC.
5.4.1. When Power Is Turned On
After power supplied and about 5 seconds passed, PC side opens 1 second, and FC side opens 1 second, and change to
the PC cooling mode for 10 minutes.
5.4.2. Basic Control
Basically 3-way valve operation of each mode as shown under the below.