IMPORTANT SAFETY NOTICE
There are special components used in this equipment which are important for safety. These parts are marked by
in the Schematic Diagrams, Circuit Board Diagrams, Exploded Views and Replacement Parts List. It is essential that
these critical parts should be replaced with manufacturer’s speci ed parts to prevent shock, re or other hazards. Do
not modify the original design without permission of manufacturer.
WARNING
Refrigerator
The service information is designed for experienced repair technicians only and is not designed for use by the general
public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting
to service a product. Products powered by electricity should be serviced or repaired only by experienced professional
technicians. Any attempt to service or repair the product or products dealt within this service information by anyone
else could result in serious injury or death.
CFCs have been used in refrigerant as refrigerator and the insulation materials for many years. But it
is now known that these compounds which once seemed so ideal for use as cleaning agents and in
refrigeration systems, destroy the earth’s ozone layer as a result, an international body decided on a
total worldwide ban of harmful CFCs by the end of 1995.
Destination
Thailand, Vietnam
Malaysia, Philippines
Hong Kong, Singapore, RBD
Indonesia, India, Australia/
New Zealand
Product Colour
White(VW)/(GW)
Shinning Silver(VS)
Stainless Colour(XS)
Black(GK)
NR-BX418XS, NR-BX418VS, NR-BX418GW
NR-BX468XS, NR-BX468VS, NR-BX468GW
NR-BX41BXS, NR-BX46BXS, NR-BX41BVW
NR-BX46BVW, NR-BX418GK, NR-BX468GK
Service Manual
Order No. PAPTH151201CE
Revision : Jun.2016
NR-BX418VNR-BX468X
NR-BX41B
NR-BX46B
NR-BX468G
NR-BX468V
NR-BX41B
NR-BX46B
NR-BX418GK
NR-BX468GK

Table of Contents

Questions and Answers

  • S
    santiagoandreaAug 18, 2025
    Why is my Panasonic NR-BX468GK not cooling but the compressor is not operating?
    • C
      Christine DixonAug 18, 2025
      If your Panasonic Refrigerator isn't cooling, a potential cause might be a defective control PCB. Check if a fuse is blown or if there are defects in components like the IC or diode. Also, check PC door switch. If the “ECONAVI Led” turn off and “Quick Freezing” blinking, the cause may be Defect of FC fan motor, Poor connection between FC fan motor and IC 1 on PCB, Defect of FC door SW., Defect of damper. If the “ECONAVI Led” turn off and “Quick Freezing” turn on, the cause may be Break of FCC thermistor, Poor connection between FCC thermistor and IC 1 on PCB, Abnormal of spec of DFC thermistor, Resistor of thermistor is bigger as like as 5.9 - 6.5 K at 0°C.
  • C
    colekristinaAug 27, 2025
    What to do if my Panasonic NR-BX468GK is not cooling due to a FC thermistor issue?
    • T
      Tammie ReyesAug 28, 2025
      If your Panasonic Refrigerator isn't cooling, and the compressor isn't operating, it could be due to a break in the FC thermistor. In this case, the “ECONAVI Led” turn on and “Quick Freezing” will be blinking. Check the FC thermistor for continuity and proper function.
  • S
    Sydney WilliamsNov 8, 2025
    What to do if my Panasonic NR-BX468GK Refrigerator is not cooling at all?
    • P
      Patricia FarrellNov 8, 2025
      If your Panasonic Refrigerator isn't cooling in either the PC or FC (compressor not operating), start by checking the power supply. Ensure the power cord is properly connected and inspect the ELCB. Also, the issue might be a defect of the overload relay, which could cause a fuse to blow. If the “ECONAVI Led” and “Quick Freezing” blink, the cause may be Compressor lock, Leakage, Droping voltage of power supply, Rising voltage of power supply, Short of DFC thermistor, Poor connection between DFC thermistor and IC 1 on PCB, Break of DFC thermistor, Defect of PCB as like as defect of relay, etc., Termal fuse blows, Abnormal of spec of DFC thermistor, When resistor of thermistor is bigger as like as 6.1 - 6.7K at 0°C, there is some case to blow thermal fuse out due to becoming defrost time long...

Summary

Safety Cautions for Repairing

1.1 Warnings

Critical safety warnings for refrigerator repair procedures, including unplugging the unit and using authentic parts.

1.2 Cautions

Precautions regarding hot parts, refrigerant, sharp edges, and transportation during service.

Specification and Components (NR-BX418 Series)

NR-BX418 Series Model Specifications

Detailed specifications for NR-BX418 series models, including destination and electrical parts.

Specification and Components (NR-BX468 Series)

NR-BX468 Series Model Specifications

Detailed specifications for NR-BX468 series models, including destination and electrical parts.

Performance Data

Self Protecting Function

5.1 Protection for IC

Logic flow for IC protection against IPM signals and compressor stoppage.

Protection for Compressor Locked

Protection mechanism for compressor lock based on RPM detection.

Protection for Power Supply Dropping

Protection logic for the compressor during power supply voltage drops.

Self Diagnosing Function

How to Use Self Diagnosing

Step-by-step instructions for initiating and using the self-diagnosing function.

Failure Mode & LED Indicators

Table of failure modes, diagnostic codes, and corresponding LED indicator status.

Temperature Control

7.1 Temperature Control (NR-BX418 Series)

Temperature adjustment for Fridge, Prime Fresh, and Freezer rooms in specific models.

Temperature Control (Fine Adjustment Mode)

Operation

Troubleshooting Guide

10.1 Not Cool at All (Compressor Not Operating)

Troubleshooting steps for refrigerators that are not cooling, with compressor off.

10.2 Cool, Not Enough (Compressor Operating)

Troubleshooting steps for insufficient cooling when the compressor is running.

Insufficient Cooling Troubleshooting

Checking Cold Air Spout

Procedures to check cold air flow from the fan and PC door.

Diagnosing Cooling Issues

Fault diagnosis based on LED indicators, thermistors, and fuses.

ECONAVI Operation Issues

Troubleshooting ECONAVI Not Working

Steps to diagnose why the ECONAVI function is not operating correctly.

Schematic Diagram

Wiring Diagram (NR-BX418 V;468 V;41 BVW;46 BVW Series)

Disassembly Instruction

PAS-Operated Control (Door) for G Type

PAS-Operated Control (Door) for X Type

Cover Damper PC; Fan Motor

Replacement Parts List (NR-BX418, NR-BX41 B)

Replacement Parts List (NR-BX418, NR-BX41 B) - Continued

Replacement Parts List (NR-BX468, NR-BX46 B)

Replacement Parts List (NR-BX468, NR-BX46 B) - Continued

Panasonic NR-BX468GK Specifications

General IconGeneral
Dimensions (H x W x D)1860 x 680 x 690 mm
RefrigerantR600a
Voltage220-240V
Frequency50 Hz
Width680 mm
Energy Efficiency ClassA++
Climate ClassNA
Freezing CapacityNA
Noise LevelNA
Annual Energy Consumption337 kWh
Defrosting SystemAutomatic
Ice MakerYes