1-13-9
Outdoor air intake temp(°C W.B.)
Model
Power
Source
Ambient
Return
Air
-15°C -8°C 6°C 8°C 15°C
DB TC IPT TC IPT TC IPT TC IPT TC IPT
S-125PU2E5B
U-125PZ2R5
(U-125PZ2R8)
230V-240V
50Hz 1phase
(400V-415V
50Hz 3phase)
16 10.2 5.24 15.7 6.17 16.2 3.97 17.2 4.08 19.3 3.98
20 9.5 5.54 14.5 6.53 15.0 4.20 15.9 4.32 17.9 4.21
24 8.8 5.63 13.6 6.64 14.0 4.27 14.9 4.39 16.8 4.28
S-125PE1R5B
U-125PZ2R5
(U-125PZ2R8)
230V-240V
50Hz 1phase
(400V-415V
50Hz 3phase)
16 10.2 5.62 15.7 6.62 16.2 4.26 17.2 4.38 19.3 4.27
20 9.5 5.95 14.5 7.01 15.0 4.51 15.9 4.64 17.9 4.52
24 8.8 6.04 13.6 7.12 14.0 4.58 14.9 4.71 16.8 4.59
S-125PT2E5B
U-125PZ2R5
(U-125PZ2R8)
230V-240V
50Hz 1phase
(400V-415V
50Hz 3phase)
16 10.2 5.49 15.7 6.46 16.2 4.16 17.2 4.28 19.3 4.17
20 9.5 5.81 14.5 6.84 15.0 4.40 15.9 4.53 17.9 4.41
24 8.8 5.90 13.6 6.95 14.0 4.47 14.9 4.60 16.8 4.48
S-125PF1E5B
U-125PZ2R5
(U-125PZ2R8)
230V-240V
50Hz 1phase
(400V-415V
50Hz 3phase)
16 10.2 5.43 15.7 6.39 16.2 4.11 17.2 4.23 19.3 4.12
20 9.5 5.74 14.5 6.76 15.0 4.35 15.9 4.48 17.9 4.36
24 8.8 5.84 13.6 6.87 14.0 4.42 14.9 4.55 16.8 4.43
1-13. Capacity Table
2. Heating Capacity Performance Data
U-125PZ2R5 (U-125PZ2R8)
TC :Heating Capacity
IPT :Heating Power Consumption
unit : kW