4 - 6
1. Outdoor Unit
1
2
3
4
5
6
7
8
9
3WAY VRF SYSTEM Unit Specifications
*1 It’s necessary to charge additional refrigerant of 70.5 oz (2.0 k
g
) per one outdoor unit.
*2 Width of product dimention in installation for multiple units is described by using Min unit clearance 60mm.
If installation hole pitch is 730mm or using snow-proof ducting, unit clearance should be 180mm.
*3 If the longest tubing equivalent length exceeds 295 ft. (90m), increase the sizes of the main tubes by 1 rank for suction tubes, discharge tubes
and liquid tubes.
With combination model, the specication of each outdoor unit is listed in [ ] , and connected by “+” .
Unit Specications (5)
Outdoor unit
Combination Model Name WU-264MF2U9 WU-288MF2U9
Single Model Name
U-120MF2U9
U-144MF2U9
U-144MF2U9
U-144MF2U9
Performance test condition AHRI Standard 1230 AHRI Standard 1230
Nominal
Cooling capacity Btu/h (kW) 264,000 (77.4) 288,000 (84.4)
Heating capacity Btu/h (kW) 297,000 (87.0) 324,000 (94.9)
Rating
Standard
AHRI 1230
Indoor unit Ducted (Type F2) Ducted (Type F2)
Cooling
Capacity Btu/h 250,000 262,000
EER 9.5 9.3
IEER 18.8 18.9
SCHE 22.4 19.2
High Heating
47F
Capacity Btu/h 274,000 278,000
COP 3.20 3.21
Low Heating
17F
Capacity Btu/h 192,000 200,000
COP 2.39 2.34
Power supply Ø, V/Hz 3Ø 208/230V 60Hz 3Ø 208/230V 60Hz
Electrical
Ratings
Outdoor
Unit only
Voltage V 208 / 230 208 / 230
Ducted cooling
Amperes A 71.0 / 64.9 76.1 / 69.6
Power input kW 24.3 / 24.3 26.1 / 26.1
Power factor % 95 / 94 95 / 94
Ducted
heating
Amperes A 67.9 / 62.0 68.4 / 62.5
Power input kW 23.2 / 23.2 23.4 / 23.4
Power factor % 95 / 94 95 / 94
Starting amperes A 1 / 1 1 / 1
Min Circuit Ampacity A - -
Max Overcurrent Protection A - -
Design Pressure
High side psi - -
Low side psi - -
Operation sound dB(A) 61.0 (Quiet mode : 58.0) 61.0 (Quiet mode : 58.0)
Compressor
Type/Quantity Inverter driven Rotary / 2 + 2 Inverter driven Rotary / 2 + 2
Motor output kW - -
Refrigeration oil
Type FV68S (Ether oil) FV68S (Ether oil)
Charge amount gal(liters) [1.53 (5.8)] + [1.53 (5.8)] [1.53 (5.8)] + [1.53 (5.8)]
Crankcase heater W [30+30] + [30+30] (at 230 V) [30+30] + [30+30] (at 230 V)
Capacity control range % 6 - 100 6 - 100
Fan
Type/Quantity Propeller / 1 + 1 Propeller / 1 + 1
Air ow CFM [9,000] + [9,000] [9,000] + [9,000]
External static pressure Pa (in. WC) 0 ~ 80 (0 ~ 0.32) 0 ~ 80 (0 ~ 0.32)
Fan motor output
W / Pole number
[750] + [750] / 8 [750] + [750] / 8
Refrigerant amount at shipment lbs. , oz (k
g
) R410A / 18.3, 293 (8.3) *
1
R410A / 18.3, 293 (8.3) *
1
Refrigerant control Electronic expantion valve Electronic expantion valve
Defrost method Reverse-cycle defrost Reverse-cycle defrost
Coil face area:(sq. ft.) / Number of rows 37.8 / 3 + 37.8 / 3 37.8 / 3 + 37.8 / 3
High pressure switch Yes Yes
Overcurrent (CT Method) Yes Yes
External nish Polyester powder double coating Polyester powder double coating
Product dimension
Height inch (mm) 72-33/64 (1842) 72-33/64 (1842)
Width inch (mm) 95-9/32 (2420) *
2
95-9/32 (2420) *
2
Depth inch (mm) 39-3/8 (1000) 39-3/8 (1000)
Packing dimension
Height inch (mm) - -
Width inch (mm) - -
Depth inch (mm) - -
Weight
NET lbs(k
g
) [752 (341)] + [756 (343)] [756 (343)] + [756 (343)]
GROSS lbs(k
g
) - -
Layers limit - -
Operation condition
(Outdoor)
Cool °F/°C DB 14 ~ 122 / -10 ~ 50 14 ~ 122 / -10 ~ 50
Heat
°F/°C DB -13 ~ 75 / -25 ~ 24 -13 ~ 75 / -25 ~ 24
°F/°C WB -13 ~ 64 / -25 ~ 17.8 -13 ~ 64 / -25 ~ 17.8
Heat & Cool
°F/°C DB 14 ~ 75 / -10 ~ 24 14 ~ 75 / -10 ~ 24
°F/°C WB - ~ 64 / - ~ 17.8 - ~ 64 / - ~ 17.8
PIPING
Pipe diameter inch (mm)
(Over 295 ft(90m) for ultimate Indoor unit.)
(Liquid) 5/8(15.88) (Discharge) 7/8 (22.22)
(Suction) 1-1/8 (28.58) (Balance) 1/4 (6.35)
((Liquid) 3/4 (19.05) (Discharge) 1-1/8 (28.58)
(Suction) 1-3/8 (34.92)) *
3
(Liquid) 5/8(15.88) (Discharge) 7/8 (22.22)
(Suction) 1-1/8 (28.58) (Balance) 1/4 (6.35)
((Liquid) 3/4 (19.05) (Discharge) 1-1/8 (28.58)
(Suction) 1-3/8 (34.92)) *
3
Connecting method - -
Pipe length range Ft(m) - ~ 1640 ( - ~ 500) - ~ 1640 ( - ~ 500)
Indoor unit & Outdoor unit height difference
(Outdoor unit upper / Outdoor unit lower) Ft (m)
164 / 131 (50 / 40) 164 / 131 (50 / 40)
The number of the indoor unit most connection 52 52
Primary accessories
Connection tubing (ID Ø3/4”-OD Ø7/8”) × 2
Connection tubing (ID Ø1”-OD Ø1-1/8”) × 2
Connection tubing (ID Ø3/4”-OD Ø7/8”) × 2
Connection tubing (ID Ø1”-OD Ø1-1/8”) × 2
Color (Munsell code) Ivory (2.6Y7.6/1.1) Ivory (2.6Y7.6/1.1)
TD831183-00_北米向け3WAY.indb 6 2015/12/10 19:35:47