EasyManua.ls Logo

Panasonic S-1821PT3H - User Manual

Panasonic S-1821PT3H
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ACXF55-31060
B.Indonesia Tiếng Vit
中文
B.Malaysia English
Operating Instructions
Air Conditioner
Model No.
Indoor Unit Outdoor Unit
S-1821PT3H
S-2430PT3H
S-3448PT3H
U-18PR1H5-1
U-21PR1H5-1
U-18PR1H5
U-21PR1H5
U-24PR1H5-1
U-30PR1H5-1
U-24PR1H5
U-30PR1H5
U-34PR1H5-1
U-43PR1H5-1
U-48PR1H5-1
U-43PR1H8-1
U-48PR1H8-1
U-34PR1H5
U-43PR1H5
U-48PR1H5
U-43PR1H8
U-48PR1H8
n
anoeX
POWE
R
TIMER
AUTO
Operating Instructions
Air Conditioner
2-21
Before operating the unit, please read these operating
instructions thoroughly and keep them for future reference.
Before installation, the installer should:
Read the Installation Instructions, then request the customer
keep them for future reference.
Arahan Operasi
Penyaman Udara
22-41
Sebelum menggunakan unit ini, sila baca arahan operasi ini
dengan teliti dan simpan untuk rujukan masa depan.
Sebelum pemasangan, pemasang perlu:
Membaca Arahan Pemasangan, kemudian minta pelanggan
menyimpannya untuk rujukan di masa depan.
操作說明書
空調器
42-61
在操作空調器前,請細讀此操作說明,並保存此書以備日後參
考。
安裝前,安裝人員應:
閱讀安裝說明,並要求顧客保留此安裝説明以備將來參考。
取出包裝在室内機箱子的遙控器。
Hướng dn s dng
Máy điu hòa không khí
62-81
Trước khi bt thiết b, vui lòng đọc k hướng dn s dng này
và gi li để tham kho cho nhng ln sau.
Trước khi lp đặt, người lp đặt nên:
Đọc hướng dn lp đặt và yêu cu khách hàng ct gi bn
hướng dn để tham kho sau này.
Petunjuk Pengoperasian
Pendingin Ruangan
82-101
Sebelum mengoperasikan unit, silahkan dibaca terlebih
dahulu petunjuk pengoperasian secara teliti dan simpan untuk
referensi selanjutnya.
Sebelum pemasangan, installer harus:
Membaca Petunjuk Pemasangan, lalu meminta pelanggan
menyimpannya untuk referensi selanjutnya.
No. Reg.: IMKG.1253.06.2021
(S-1821PT3H, S-2430PT3H, S-3448PT3H, U-18PR1H5,
U-21PR1H5, U-24PR1H5, U-30PR1H5, U-34PR1H5,
U-43PR1H5, U-48PR1H5, U-43PR1H8, U-48PR1H8)
Question and Answer IconNeed help?

Do you have a question about the Panasonic S-1821PT3H and is the answer not in the manual?

Overview

This document is an operating manual for a Panasonic Air Conditioner, covering models S-1821PT3H, S-2430PT3H, S-3448PT3H for indoor units and U-18PR1H5-1, U-21PR1H5-1, U-18PR1H5, U-21PR1H5, U-24PR1H5-1, U-30PR1H5-1, U-24PR1H5, U-30PR1H5, U-34PR1H5-1, U-43PR1H5-1, U-48PR1H5-1, U-43PR1H8-1, U-48PR1H8-1, U-34PR1H5, U-43PR1H5, U-48PR1H5, U-43PR1H8, U-48PR1H8 for outdoor units. The manual provides instructions in English, Bahasa Malaysia, Chinese, Tiếng Việt, and Bahasa Indonesia.

Function Description:

The Panasonic Air Conditioner is designed to provide efficient and comfortable cooling, air circulation, and dehumidification for indoor spaces. It features a remote control for easy operation and offers various modes to suit user needs. The unit incorporates nanoe™X technology for a fresher and cleaner environment, which automatically activates upon startup and can also be manually controlled. The system includes an auto-restart control that resumes operation with the last settings after a power failure. A timer function allows users to set specific ON or OFF times for the unit, with daily repetition.

Important Technical Specifications:

  • Refrigerant: R32 (mildly flammable refrigerant). Special precautions are outlined for handling R32, including specific piping and installation tools due to higher working pressure compared to R22 models. The charging port thread diameter for R32 and R410A is 1/2 inch.
  • Temperature Selection Range: 16.0 °C ~ 30.0 °C (60 °F ~ 86 °F) for COOL and DRY modes (not applicable for FAN mode).
  • Energy Saving Temperature Setting (COOL mode): Recommended range of 26.0 °C ~ 28.0 °C (79 °F ~ 82 °F).
  • Operating Conditions (COOL mode): Maximum indoor temperature of 32 °C (89.6 °F) and outdoor temperature of 46 °C (114.8 °F). Minimum indoor temperature of 16 °C (60.8 °F) and outdoor temperature of 16 °C (60.8 °F).
  • Remote Control: Uses 2 AAA or R03 batteries. Effective range is within 8 meters from the indoor unit's receiver.
  • Optional Wired Remote Controllers: Timer Remote Controller (CZ-RTC4), High-spec Wired Remote Controller (CZ-RTC5B), and Wired Remote Controller (CZ-RTC6 series) are available for separate purchase.

Usage Features:

  • Basic Operation: Start/stop the unit, select operating modes (FAN, COOL, DRY), and adjust the desired temperature using the remote control.
  • Fan Speed Adjustment: The fan speed can be adjusted as desired via the remote control.
  • Airflow Direction Adjustment: The unit supports automatic horizontal flap swing and offers 5 options for manual airflow direction. The vertical flap is manually adjustable. The "AUTO" airflow setting helps keep the room ventilated.
  • nanoe™X Function: Automatically starts when the unit is turned on to provide a fresher and cleaner environment. It can be manually turned OFF and activated even when the unit is OFF.
  • Timer Setting: Allows programming the unit to turn ON or OFF at a preset time. The timer operation follows the remote control's clock setting and repeats daily.
  • Auto Restart Control: In case of a power failure, the unit automatically restarts with the last operation mode and airflow direction once power is restored.
  • Temperature Display: The remote control can display temperature in either °C or °F by pressing the temperature button for approximately 10 seconds.

Maintenance Features:

  • Regular Cleaning: Recommended for optimal performance. A dirty unit may malfunction. Consult an authorized dealer for internal cleaning.
  • Indoor Unit Cleaning: Wipe gently with a soft, dry cloth. Coils and fans should be cleaned periodically by an authorized dealer.
  • Outdoor Unit Cleaning: Clean debris around the unit and clear any blockages from the drain pipe.
  • Air Filter Removal and Installation:
    1. Remove screws on both sides.
    2. Push knobs on the intake grille to open it.
    3. Remove air filters from the intake grille tabs.
    4. Install by reversing the removal procedure.
    5. Close and push knobs to secure the intake grille.
    6. Firmly tighten screws on both sides.
    • Do not remove the string to prevent the intake grille from falling.
  • Air Filter Maintenance: Recommended to clean air filters every 6 weeks. After cleaning, press the "FILTER RESET" button on the remote control to reset the filter indicator.
  • Troubleshooting: The manual includes a comprehensive section for identifying and resolving common issues, as well as retrieving error codes if the unit stops and the TIMER indicator blinks. Users are advised to consult an authorized dealer for issues that cannot be resolved through basic troubleshooting.
  • Extended Non-Use: For long periods of non-use, activate FAN mode for 2-3 hours to remove moisture, turn off the power supply, unplug the unit, and remove batteries from the remote control to prevent mold growth.

Safety Precautions:

The manual emphasizes strict adherence to safety precautions, especially concerning R32 refrigerant, to prevent personal injury, property damage, electric shock, or fire. It includes warnings about proper installation, maintenance, and disposal procedures, as well as guidelines for handling electrical components and detecting refrigerant leaks. It also advises against using modified cords, operating with wet hands, or blocking ventilation openings.

Panasonic S-1821PT3H Specifications

General IconGeneral
BrandPanasonic
ModelS-1821PT3H
CategoryAir Conditioner
LanguageEnglish

Related product manuals