22. Combination Characteristic
Calculation method of indoor unit capacity
(Example)
Outdoor unit: U-8EA1E8
Indoor unit: S-36KA1E5 x 3 + S-56KA1E5 + S-63KA1E5
Actual cooling capacity of S-56KA1E5
indoor rated cooling capacity (5.6kW)
Cooling capacity (22.4kW) ×
= 5.53kW
Total indoor rated cooling capacity (22.7kW)
Indoor Unit Cooling Capacity (kW)
Indoor unit 0.8HP 1.0HP 1.25HP 1.5HP 1.65HP 1.75HP 2.0HP 2.5HP 3.0HP 3.5HP 4.0HP 5.0HP
Cooling
capacity
2.2kW 2.8kW 3.2kW 3.6kW 4.0kW 4.5kW 5.6kW 6.3kW 7.1kW 9.0kW 10.0kW 12.5kW
Wall mounted
Mini cassette
Big cassette
Duct D4
Cooling
Duct D3
U-8EA1E8